Metraipolis › archive › dc_65cc64991d7c

One Frame, Full Heartbeat: ECG-Free Cardiac Cine MRI Synthesis via Phase-Conditioned Flow Matching — arXiv:2610.09397

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.09397
License (as archived)
CC0-1.0
Archived
2026-10-08T12:47:12.702Z
SHA-256 of the archived text
ed908524e8ce35b75e31aabd672444bf4e759b70eb907f15c03c745154272f6c
Stable URL of this page
https://metraipolis.com/documento/dc_65cc64991d7c

How to cite

One Frame, Full Heartbeat: ECG-Free Cardiac Cine MRI Synthesis via Phase-Conditioned Flow Matching — arXiv:2610.09397 — arXiv (en), https://arxiv.org/abs/2610.09397 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_65cc64991d7c (Metraipolis archive dc_65cc64991d7c, sha256 ed908524e8ce35b75e31aabd672444bf4e759b70eb907f15c03c745154272f6c)
BibTeX
@misc{dc65cc64991d7c,
  title = {One Frame, Full Heartbeat: ECG-Free Cardiac Cine MRI Synthesis via Phase-Conditioned Flow Matching — arXiv:2610.09397},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.09397},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_65cc64991d7c; sha256 ed908524e8ce35b75e31aabd672444bf4e759b70eb907f15c03c745154272f6c},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.09397. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Cine cardiovascular magnetic resonance (CMR) analysis relies on multi-frame sequences capturing the full cardiac cycle. However, standard multi-frame acquisition depends heavily on electrocardiogram (ECG) gating and repeated breath-holds, posing challenges in uncooperative populations, resource-limited settings, and temporally corrupted datasets. Existing methods that synthesize full cardiac sequences either rely on explicit ECG signals to parameterize myocardium function, or employ deformable registration without physiological constraints, failing to faithfully reproduce clinically relevant dynamic metrics such as ejection fraction (EF) and ventricular contraction magnitude. We present PhaseFlow, a unified generative framework that overcomes both limitations. PhaseFlow estimates a non-linear cardiac phase signal directly from the input sequence via a segmentation-derived left-ventricular (LV) area curve, capturing the asymmetric dynamics of systole and diastole without any ECG dependency. At inference, this phase signal is provided by a pathology-specific template, informing phase-specific frame generation. A rectified flow model conditioned on the phase and slice position synthesizes the full cardiac motion trajectory in the latent space, decoded into a diffeomorphic displacement field that warps end-diastole pixel intensities directly, eliminating the reconstruction blur often accompanying the variational autoencoder. On the ACDC benchmark, PhaseFlow achieves superior physiological fidelity and image realism, with best LV volume curve $R^2$, structural similarity (SSIM) and generative quality (FID) among all baselines. Ablation studies confirm that each proposed component contributes measurably to the overall performance.

Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.CV, nuovi lavori del giorno).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2610.09397 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-08T12:18:15.352Z dalla pagina https://arxiv.org/list/cs.CV/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).