Metraipolis › archive › dc_65c7ef2498b1
Dielectric Models of Normal and Diseased Human Trabecular Bones at Microwave Frequencies — arXiv:2611.04160
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2611.04160
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-04T19:14:20.469Z
- SHA-256 of the archived text
050bdc650f03ba0aac1b7828297a1f7e461cfe74137cae54ea0271e1e0ae5b5c- Stable URL of this page
https://metraipolis.com/documento/dc_65c7ef2498b1
How to cite
Dielectric Models of Normal and Diseased Human Trabecular Bones at Microwave Frequencies — arXiv:2611.04160 — arXiv (en), https://arxiv.org/abs/2611.04160 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_65c7ef2498b1 (Metraipolis archive dc_65c7ef2498b1, sha256 050bdc650f03ba0aac1b7828297a1f7e461cfe74137cae54ea0271e1e0ae5b5c)
BibTeX
@misc{dc65c7ef2498b1,
title = {Dielectric Models of Normal and Diseased Human Trabecular Bones at Microwave Frequencies — arXiv:2611.04160},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2611.04160},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_65c7ef2498b1; sha256 050bdc650f03ba0aac1b7828297a1f7e461cfe74137cae54ea0271e1e0ae5b5c},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.04160. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
The dielectric properties of biological tissues are used to investigate the interaction of electromagnetic (EM) fields with the human body. These properties are integrated into EM numerical simulations, such as the finite difference time domain (FDTD) method, using dielectric models such as Cole-Cole and Debye models. These computational tools are employed to study the propagation of EM waves within the human body. This paper has developed the one-pole and two-pole Cole-Cole and Debye models for the dielectric properties of normal and diseased human trabecular bone tissue at microwave frequencies (0.5-8.5 GHz). The dielectric properties of normal trabecular and cortical bone were derived based on the literature, while those of diseased human trabecular bones (osteoporotic and osteoarthritis) were acquired from a previous study conducted by the authors, which characterised the properties within the 0.5-8.5 GHz frequency range. This study has employed a weighted least squares method to optimise the one-pole and two-pole dielectric models' parameters. The accuracy of the developed dielectric models is validated by comparing the simulated results with the experimental data already published by the authors. The comparative analysis of the models demonstrated that the one-pole Cole-Cole model achieved a better fit compared to the one-pole Debye model across all bone types. Additionally, the two-pole Cole-Cole model exhibited a better fit than the two-pole Debye model. The proposed models can be used in numerical simulations to investigate the interaction of EM fields with bone tissue and develop and optimise microwave bone health monitoring and treatment techniques. Tema degli esploratori: statistica e scienza dei dati (elenco arXiv eess.SP, nuovi lavori del giorno). Categorie arXiv: Medical Physics (physics.med-ph) ; Signal Processing (eess.SP); Biological Physics (physics.bio-ph). Pagina del lavoro: https://arxiv.org/abs/2611.04160 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-11-04T18:48:39.258Z dalla pagina https://arxiv.org/list/eess.SP/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).