Metraipolis › archive › dc_657e5a0b86e7
BEAM3R: Beam's-eye-view architecture with Mamba-3 for implicit dose reconstruction — arXiv:2609.04747
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.04747
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-16T23:44:24.860Z
- SHA-256 of the archived text
32af263224d46775f948f95aaaffcd4e1e685e170f55cf6bc0d33ca4b7406e4f- Stable URL of this page
https://metraipolis.com/documento/dc_657e5a0b86e7
How to cite
BEAM3R: Beam's-eye-view architecture with Mamba-3 for implicit dose reconstruction — arXiv:2609.04747 — arXiv (en), https://arxiv.org/abs/2609.04747 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_657e5a0b86e7 (Metraipolis archive dc_657e5a0b86e7, sha256 32af263224d46775f948f95aaaffcd4e1e685e170f55cf6bc0d33ca4b7406e4f)
BibTeX
@misc{dc657e5a0b86e7,
title = {BEAM3R: Beam's-eye-view architecture with Mamba-3 for implicit dose reconstruction — arXiv:2609.04747},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.04747},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_657e5a0b86e7; sha256 32af263224d46775f948f95aaaffcd4e1e685e170f55cf6bc0d33ca4b7406e4f},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.04747. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
To enable accurate and rapid photon control point and proton beamlet dose calculation in the DoseRAD2026 challenge, we present BEAM3R, a dose estimation framework operating in beam's-eye-view (BEV). Our core innovation combines a Mamba-3 state-space depth-sequence core with physics-based transport conditioning to model long-range depth transport without expensive 3D convolutions. BEAM3R shares a 2D CNN encoder-decoder architecture for photon and proton dose tasks, processing per-plane BEV slices. Proton beamlets are conditioned on water equivalent thickness and remaining range, encoding the parameters determining Bragg peak position. Photon models use a bidirectional Mamba-3 core to capture dose contributions from materials downstream of the calculation point, while the proton model uses a forward core with learned energy-prefix tokens and a Bragg-peak refinement module. To reduce interpolation artifacts and support high spatial resolution, we introduce axial grid alignment of BEV lattices with CT slices and an implicit super-resolution representation via sub-pixel phase packing, evaluated by a differentiable Triton-accelerated resampler that reconstructs packed cubic B-spline coefficients directly in CT space. For MRI-based tasks, synthetic CTs (sCT) are generated by a patch-based conditional GAN with a SwinUNETR backbone. On the preliminary DoseRAD2026 test set, CT-to-photon and CT-to-proton models achieved 1%/1 mm local gamma pass rates of 96.8% and 96.0%, with stratified plan-level MAEs of 0.0041 and 0.0079. Substituting sCT reduced gamma pass rates to 89.7% for photon and 75.4% proton plan level doses, with stratified plan-level MAEs of 0.0093 and 0.0336. Standardised runtimes were 23.4 s and 18.4 s for CT-to-photon and CT-to-proton prediction, increasing to 39.7 s and 42.8 s for the corresponding MRI-based pipelines. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-07 in cs.CV). Categorie arXiv: Medical Physics (physics.med-ph) ; Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2609.04747 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-16T23:16:11.492Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-07?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).