Metraipolis › archive › dc_651f0e85bc07
Task-driven sparse-view planar X-ray computed tomography for axial metrology — arXiv:2611.01537
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2611.01537
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-03T18:56:50.809Z
- SHA-256 of the archived text
94437181dd64f7dba43dd88cf42dec531d7f360880fb0a29edccdc2a51661de0- Stable URL of this page
https://metraipolis.com/documento/dc_651f0e85bc07
How to cite
Task-driven sparse-view planar X-ray computed tomography for axial metrology — arXiv:2611.01537 — arXiv (en), https://arxiv.org/abs/2611.01537 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_651f0e85bc07 (Metraipolis archive dc_651f0e85bc07, sha256 94437181dd64f7dba43dd88cf42dec531d7f360880fb0a29edccdc2a51661de0)
BibTeX
@misc{dc651f0e85bc07,
title = {Task-driven sparse-view planar X-ray computed tomography for axial metrology — arXiv:2611.01537},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2611.01537},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_651f0e85bc07; sha256 94437181dd64f7dba43dd88cf42dec531d7f360880fb0a29edccdc2a51661de0},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.01537. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Computational imaging can reduce the acquisition burden when the system is designed around task-relevant information rather than complete image recovery. We investigate this framework for sparse-view planar X-ray tomography (XCT) of layered objects, using measurement of the axial termination gap (ATG) of back-drilled printed-circuit-board (PCB) vias as a representative task. Instead of using 3D reconstruction, the proposed method estimates ATG directly from polychromatic projection data through a physics-based sensitivity model. A gated hierarchical estimator first fits ATG together with radiometric perturbations and selectively introduces global geometry and specimen-warp models only when a reduced chi-squared adequacy test and Bayesian information criterion justify the added degrees of freedom. The same low-dimensional perturbation model is incorporated into marginalized Fisher-information analyses, yielding task-specific conditional and calibration-aware Cram'er-Rao bounds. Numerical experiments show that, under a fixed total photon budget, task-driven metrology changes little over 12-64 views, while reconstruction-driven metrology is strongly view-dependent with much larger errors. The direct estimator also follows the expected photon-limited scaling. These results demonstrate a computational sensing strategy in which XCT acquisition, physical modeling, and inference are evaluated according to the quantitative information required by the task rather than for general-purpose volumetric image fidelity. Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.CV, nuovi lavori del giorno). Categorie arXiv: Image and Video Processing (eess.IV) ; Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2611.01537 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-11-03T18:16:53.110Z dalla pagina https://arxiv.org/list/cs.CV/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).