Metraipolis › archive › dc_64b69703ca4c
YOLO-PVC: 2D-to-3D Consolidation of Slice-wise Detections for Volumetric Liver Tumor Localization in MRI — arXiv:2608.04642
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.04642
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-31T11:48:03.172Z
- SHA-256 of the archived text
440116c464bb6ea8f5f3370ccbc1c6d052cf44428c11a7d966645e498aa111f3- Stable URL of this page
https://metraipolis.com/documento/dc_64b69703ca4c
How to cite
YOLO-PVC: 2D-to-3D Consolidation of Slice-wise Detections for Volumetric Liver Tumor Localization in MRI — arXiv:2608.04642 — arXiv (en), https://arxiv.org/abs/2608.04642 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_64b69703ca4c (Metraipolis archive dc_64b69703ca4c, sha256 440116c464bb6ea8f5f3370ccbc1c6d052cf44428c11a7d966645e498aa111f3)
BibTeX
@misc{dc64b69703ca4c,
title = {YOLO-PVC: 2D-to-3D Consolidation of Slice-wise Detections for Volumetric Liver Tumor Localization in MRI — arXiv:2608.04642},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.04642},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_64b69703ca4c; sha256 440116c464bb6ea8f5f3370ccbc1c6d052cf44428c11a7d966645e498aa111f3},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.04642. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Slice-wise 2D object detectors are increasingly applied to volumetric data due to their computational efficiency and scalability, yet they often yield fragmented and unstable predictions along the depth axis. We propose YOLO-PVC, a lightweight and model-agnostic framework for 2D-to-3D consolidation of slice-wise detections. The method enforces depth continuity, aggregates bounding box coordinates using robust percentile statistics, and further refines axial extent through a lightweight MLP-based calibration module. Unlike naïve stacking or averaging strategies, YOLO-PVC explicitly addresses missing detections and outlier slices along the depth dimension. Experiments on 3D liver MRI volumes across three tumor categories demonstrate consistent improvements over multiple aggregation baselines. The heuristic PVC achieves an overall $\mathrm{IoU}_{3D}$ of $0.665$, while the calibrated variant further improves performance to $0.710$, with high planar overlap ($\mathrm{BEV\ IoU} \approx 0.78$). These results demonstrate that structured geometric consolidation provides an effective and practical solution for volumetric liver tumor localization in clinical MRI.
Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-08-06 in cs.CV).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2608.04642 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-31T11:37:40.697Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-08-06?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).