Metraipolis › archive › dc_6432244ab4fa

OpenMASC: An Open-Source Pipeline for Cross-Trajectory Metal-Aware Sampling and Correction in Accelerated MRI — arXiv:2609.32343

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.32343
License (as archived)
CC0-1.0
Archived
2026-10-07T23:50:51.490Z
SHA-256 of the archived text
e44878535932c1792bf0dba570e788826c236989254b472f5ffbc9c66703576b
Stable URL of this page
https://metraipolis.com/documento/dc_6432244ab4fa

How to cite

OpenMASC: An Open-Source Pipeline for Cross-Trajectory Metal-Aware Sampling and Correction in Accelerated MRI — arXiv:2609.32343 — arXiv (en), https://arxiv.org/abs/2609.32343 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_6432244ab4fa (Metraipolis archive dc_6432244ab4fa, sha256 e44878535932c1792bf0dba570e788826c236989254b472f5ffbc9c66703576b)
BibTeX
@misc{dc6432244ab4fa,
  title = {OpenMASC: An Open-Source Pipeline for Cross-Trajectory Metal-Aware Sampling and Correction in Accelerated MRI — arXiv:2609.32343},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.32343},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_6432244ab4fa; sha256 e44878535932c1792bf0dba570e788826c236989254b472f5ffbc9c66703576b},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.32343. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Metal implants corrupt MRI measurements throughout $k$-space, yet existing accelerated MRI methods assume clean data and most metal artifact reduction approaches assume fully sampled acquisitions. No public dataset provides paired $k$-space and images with and without metal for the same anatomy, and no framework jointly addresses artifact-aware acquisition and reconstruction across sampling trajectories. We present OpenMASC, an open-source pipeline covering the full workflow from data generation to deployment. A physics-based data generation module converts public CT volumes into paired clean and metal-corrupted MRI data in both Cartesian and radial formats. MA-VarNet, an unrolled reconstruction network with a per-cascade DC Rectifier, corrects artifacts that data-consistency steps reintroduce from corrupted measurements. A reinforcement learning agent actively selects $k$-space readouts and co-trains with the reconstruction network through a decoupled three-stage procedure. The framework is trajectory-agnostic except for the data-consistency operator, supporting both Cartesian and radial acquisition without architectural changes. Experiments on two datasets at $4\times$ and $8\times$ acceleration demonstrate consistent improvements over conventional and learned baselines on both trajectories.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-29 in cs.CV).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2609.32343 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-07T23:29:27.008Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-29?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).