Metraipolis › archive › dc_63fb05000326

nnFoundation: 3D Foundation Models for Radiology — arXiv:2609.26924

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.26924
License (as archived)
CC0-1.0
Archived
2026-10-08T12:34:35.253Z
SHA-256 of the archived text
e4415ea17c0abfb2808958433aad0ecb7db95243bc1818a870d474f858beeb62
Stable URL of this page
https://metraipolis.com/documento/dc_63fb05000326

How to cite

nnFoundation: 3D Foundation Models for Radiology — arXiv:2609.26924 — arXiv (en), https://arxiv.org/abs/2609.26924 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_63fb05000326 (Metraipolis archive dc_63fb05000326, sha256 e4415ea17c0abfb2808958433aad0ecb7db95243bc1818a870d474f858beeb62)
BibTeX
@misc{dc63fb05000326,
  title = {nnFoundation: 3D Foundation Models for Radiology — arXiv:2609.26924},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.26924},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_63fb05000326; sha256 e4415ea17c0abfb2808958433aad0ecb7db95243bc1818a870d474f858beeb62},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.26924. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Radiological artificial intelligence has advanced rapidly, yet most systems remain narrowly task-specific, data-intensive, and fragile under domain shift. Foundation models promise more transferable and data-efficient solutions, but existing approaches are limited in scale, evaluated narrowly, and often assume that a single pretrained model can support diverse downstream tasks. Here we present nnFoundation, complementary convolutional and transformer-based 3D radiological foundation models. Developed within the Human Radiome Project (THRP), nnFoundation is trained on 2.1 million CT, MRI, and PET image volumes from 125 institutional and public datasets. We evaluate them across 108 tasks spanning segmentation, detection, classification, report generation, and image retrieval, including evaluations under domain shift, by external partners and in low-data and low-compute regimes. Across all task types, our convolution- and transformer-based nnFoundation models consistently outperform both prior 3D foundation models and training from scratch, establishing state-of-the-art performance for radiological imaging. However, performance follows a consistent task-dependent structure: the convolutional nnFoundation model dominates spatially localized tasks, whereas the transformer-based nnFoundation model excels in tasks requiring global semantic reasoning and in frozen-feature settings. Dynamically aligning the foundation model topology with the dataset characteristics post-hoc further improves transfer across heterogeneous 3D settings. These results show that transferable 3D radiological performance is governed not by a single universal model, but by the interplay of scalable pretraining, complementary architectures, and dataset-aware adaptation. We release nnFoundation models integrated into nnU-Net and nnDetection, enabling immediate application across established radiology workflows.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-24 in cs.CV).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV) ; Image and Video Processing (eess.IV).
Pagina del lavoro: https://arxiv.org/abs/2609.26924 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-08T12:12:35.629Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-24?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).