Metraipolis › archive › dc_62db3da4db81

Enhancing Atrial Fibrillation Detection Through Hyperparameter Optimization — arXiv:2610.40001

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.40001
License (as archived)
CC0-1.0
Archived
2026-11-01T02:25:19.651Z
SHA-256 of the archived text
d4281b1d60abee2bf1c066f3ca6f8c0239d741d0a0230931111a6c137a5f557b
Stable URL of this page
https://metraipolis.com/documento/dc_62db3da4db81

How to cite

Enhancing Atrial Fibrillation Detection Through Hyperparameter Optimization — arXiv:2610.40001 — arXiv (en), https://arxiv.org/abs/2610.40001 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_62db3da4db81 (Metraipolis archive dc_62db3da4db81, sha256 d4281b1d60abee2bf1c066f3ca6f8c0239d741d0a0230931111a6c137a5f557b)
BibTeX
@misc{dc62db3da4db81,
  title = {Enhancing Atrial Fibrillation Detection Through Hyperparameter Optimization — arXiv:2610.40001},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.40001},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_62db3da4db81; sha256 d4281b1d60abee2bf1c066f3ca6f8c0239d741d0a0230931111a6c137a5f557b},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.40001. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

This study explores the role of hyperparameter optimization (HPO) in enhancing the detection of Atrial Fibrillation (AF) using both machine learning and deep learning models. We evaluated a range of standard classifiers - Decision Tree, Random Forest, and XGBoost classifiers, alongside deep learning architectures including Recurrent Neural Networks, Deep Neural Networks, and Siamese Neural Networks. To fine-tune these models, we applied four HPO methods: Genetic Algorithm, Hyperband, Optuna, and SMAC3. The experiments were conducted using inter-patient and intra- patient data splits to assess model generalization and robustness in the presence of class imbalance, which is reflective of real-world AF occurrence. Our results, based on PhysioNet electrocardiogram datasets, showed that the Hyperband-optimized XGBoost model outperformed all others, achieving a peak F1 score of 96.95%. These findings highlight the critical role of suitable HPO strategies in enhancing the accuracy and robustness of AF classification outcomes in clinical settings.

Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.LG, nuovi lavori del giorno).
Categorie arXiv: Machine Learning (cs.LG).
Pagina del lavoro: https://arxiv.org/abs/2610.40001 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-01T02:12:44.197Z dalla pagina https://arxiv.org/list/cs.LG/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).