Metraipolis › archive › dc_61aae461f42d
Recording Hand-Held Laparoscopic Instrument Motion in the Operating Room: Magnetometer-Free Fusion of Inertial, Range and Visual Sensing — arXiv:2609.25577
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.25577
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-08T16:43:24.855Z
- SHA-256 of the archived text
20355f8ce339b7ec975c64a3f5efc28716804e0dc40b13a72d963185945639d6- Stable URL of this page
https://metraipolis.com/documento/dc_61aae461f42d
How to cite
Recording Hand-Held Laparoscopic Instrument Motion in the Operating Room: Magnetometer-Free Fusion of Inertial, Range and Visual Sensing — arXiv:2609.25577 — arXiv (en), https://arxiv.org/abs/2609.25577 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_61aae461f42d (Metraipolis archive dc_61aae461f42d, sha256 20355f8ce339b7ec975c64a3f5efc28716804e0dc40b13a72d963185945639d6)
BibTeX
@misc{dc61aae461f42d,
title = {Recording Hand-Held Laparoscopic Instrument Motion in the Operating Room: Magnetometer-Free Fusion of Inertial, Range and Visual Sensing — arXiv:2609.25577},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.25577},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_61aae461f42d; sha256 20355f8ce339b7ec975c64a3f5efc28716804e0dc40b13a72d963185945639d6},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.25577. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Most minimally invasive procedures are still performed with hand-held laparoscopic instruments, yet only the endoscopic video is retained; the instrument motion that expresses surgical skill, and that could support skill assessment and robot learning, is lost. Pose from video alone remains millimeters to centimeters off, and an instrument-mounted inertial measurement unit (IMU) cannot rely on its magnetometer, whose field changed with tool pose and between sessions in our measurements. We present a surgical instrument-state logger that clips onto a conventional instrument without modifying the part that enters the patient and fuses a six-axis IMU and a time-of-flight (ToF) rangefinder with a markerless camera in an error-state Kalman filter under the remote center of motion (RCM) of the trocar. Heading comes from the shaft silhouette, segmented by a U-Net, in place of the magnetometer: the rotation-angle error is 0.200°, against 3.58° from the accelerometer and magnetometer alone. Against a Franka Research 3 manipulator, and without alignment to it, the displacement error over 300 translation trials was 1.21mm RMS and the relative-rotation error over 180 rotation trials 0.34° RMS. On continuous trajectories, tracked and displayed in real time, the absolute tip error was 1.22mm (programmed) and 3.04mm (teleoperated) after post-hoc tuning of three filter parameters, and the full fusion beat every sensor subset. Because the estimator uses no magnetic measurement, its accuracy does not rely on an undisturbed field. The same clip-on device could thus record metric tip trajectories during routine hand-held laparoscopy, while displaying the insertion depth and attitude that are hidden once the instrument is inside the patient. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-23 in cs.RO). Categorie arXiv: Robotics (cs.RO). Pagina del lavoro: https://arxiv.org/abs/2609.25577 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-08T15:56:53.435Z dalla pagina https://arxiv.org/catchup/cs.RO/2026-09-23?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).