Metraipolis › archive › dc_610bb7f1bc12
BSC-Net: A Small-Branch-Sensitive Structural Continuity Network for Coronary Vessel Segmentation and Quantitative Angiographic Analysis — arXiv:2609.15400
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.15400
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-16T01:53:30.384Z
- SHA-256 of the archived text
6aed1bb80ffef11da962c38117f0b0d5096d58344e70a2b30cf1b3be92c05c58- Stable URL of this page
https://metraipolis.com/documento/dc_610bb7f1bc12
How to cite
BSC-Net: A Small-Branch-Sensitive Structural Continuity Network for Coronary Vessel Segmentation and Quantitative Angiographic Analysis — arXiv:2609.15400 — arXiv (en), https://arxiv.org/abs/2609.15400 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_610bb7f1bc12 (Metraipolis archive dc_610bb7f1bc12, sha256 6aed1bb80ffef11da962c38117f0b0d5096d58344e70a2b30cf1b3be92c05c58)
BibTeX
@misc{dc610bb7f1bc12,
title = {BSC-Net: A Small-Branch-Sensitive Structural Continuity Network for Coronary Vessel Segmentation and Quantitative Angiographic Analysis — arXiv:2609.15400},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.15400},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_610bb7f1bc12; sha256 6aed1bb80ffef11da962c38117f0b0d5096d58344e70a2b30cf1b3be92c05c58},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.15400. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Vessel segmentation in X-ray coronary angiography (XCA) is a fundamental step for quantitative coronary analysis and subsequent assessment of coronary artery disease. However, accurate vessel segmentation remains challenging because of imaging noise, complex bifurcations, and the overlap of vessels and background structures, which can lead to disrupted vascular connectivity and missed small branches. In this work, we propose BSC-Net, a ResNet-U-Net-based framework tailored to improve small-vessel representation and repair vascular structural continuity. BSC-Net enhances small-vessel representation through targeted sampling and improves vascular structural continuity by integrating long-range contextual modeling and Edge-Informed Loss (EIL). BSC-Net was validated on two public XCA datasets, demonstrating state-of-the-art (SOTA) performance in coronary vessel segmentation with Dice and IoU scores of 77.8%/90.6% and 64.5%/83.0%, respectively. Furthermore, based on the obtained vessel segmentation, we performed automated quantitative coronary analysis and derived clinically relevant morphological and hemodynamic parameters, including stenosis ratio, time-to-peak, and relative propagation velocity. These results demonstrate that BSC-Net produces accurate vessel segmentation results with preserved vascular continuity for quantitative coronary assessment, enabling reliable downstream analysis and clinical evaluation of coronary artery disease. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-15 in cs.CV). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2609.15400 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-16T01:25:23.676Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-15?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).