Metraipolis › archive › dc_609b34e706f2
DiSR-ECG: Residual Shifting Conditional Diffusion for Robust ECG Super-Resolution — arXiv:2609.16619
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.16619
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-15T22:39:31.732Z
- SHA-256 of the archived text
fda6556d58c01f4ac957c30301c69281a30c687a6c13e5fbc8fc241054026a0c- Stable URL of this page
https://metraipolis.com/documento/dc_609b34e706f2
How to cite
DiSR-ECG: Residual Shifting Conditional Diffusion for Robust ECG Super-Resolution — arXiv:2609.16619 — arXiv (en), https://arxiv.org/abs/2609.16619 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_609b34e706f2 (Metraipolis archive dc_609b34e706f2, sha256 fda6556d58c01f4ac957c30301c69281a30c687a6c13e5fbc8fc241054026a0c)
BibTeX
@misc{dc609b34e706f2,
title = {DiSR-ECG: Residual Shifting Conditional Diffusion for Robust ECG Super-Resolution — arXiv:2609.16619},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.16619},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_609b34e706f2; sha256 fda6556d58c01f4ac957c30301c69281a30c687a6c13e5fbc8fc241054026a0c},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.16619. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Electrocardiogram (ECG) signals are essential for arrhythmia diagnosis. With the growing adoption of long-term monitoring via wearable and portable devices, energy-efficient acquisition has become critical, motivating the development of ECG super-resolution (SR) techniques to reconstruct high-resolution signals from low-sampling-rate inputs. While recent SR methods based on discriminative neural networks have shown strong performance, their robustness under distribution shift remains uncertain, which poses a key challenge for real-world deployment. In this study, we propose DiSR-ECG, a residual shifting conditional diffusion framework for robust ECG SR. The model integrates residual shifting with Mamba-based temporal modeling and conditional guidance to enable accurate multi-lead reconstruction. Experiments on two large-scale ECG databases, PTB-XL for in-domain evaluation and Chapman Shaoxing for cross-dataset evaluation, demonstrate that DiSR ECG achieves state-of-the-art performance in both settings, with particularly strong generalization under distribution shift. These results highlight the potential of DiSR-ECG to provide reliable and clinically applicable ECG reconstruction for real-world monitoring. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-16 in eess.SP). Categorie arXiv: Signal Processing (eess.SP). Pagina del lavoro: https://arxiv.org/abs/2609.16619 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-15T22:17:46.005Z dalla pagina https://arxiv.org/catchup/eess.SP/2026-09-16?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).