Metraipolis › archive › dc_600d839738a9

Quadratic Unconstrained Binary Optimization for Sparse Magnetoencephalography Source Localization — arXiv:2608.14738

Source
arXiv (en)
Original
https://arxiv.org/abs/2608.14738
License (as archived)
CC0-1.0
Archived
2026-10-19T02:13:52.845Z
SHA-256 of the archived text
a3b0ff9e863994d7ddd83c19847cf16385470b91150dfe09c0dc8c2e30e02cdb
Stable URL of this page
https://metraipolis.com/documento/dc_600d839738a9

How to cite

Quadratic Unconstrained Binary Optimization for Sparse Magnetoencephalography Source Localization — arXiv:2608.14738 — arXiv (en), https://arxiv.org/abs/2608.14738 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_600d839738a9 (Metraipolis archive dc_600d839738a9, sha256 a3b0ff9e863994d7ddd83c19847cf16385470b91150dfe09c0dc8c2e30e02cdb)
BibTeX
@misc{dc600d839738a9,
  title = {Quadratic Unconstrained Binary Optimization for Sparse Magnetoencephalography Source Localization — arXiv:2608.14738},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2608.14738},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_600d839738a9; sha256 a3b0ff9e863994d7ddd83c19847cf16385470b91150dfe09c0dc8c2e30e02cdb},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.14738. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Magnetoencephalography (MEG) source localization is an ill-posed inverse problem because distinct cortical source configurations can produce similar sensor-level fields. We formulate sparse multi-source localization as a quadratic unconstrained binary optimization (QUBO) problem combined with residual-aware candidate screening. Candidate source-location groups are generated from the sensor-space residual, fixed sensor-space templates are estimated for the resulting candidates, and active templates are jointly selected using data-fit, pairwise template interactions, and soft-cardinality terms. We evaluate the method using classical simulated annealing in controlled synthetic MEG simulations, primarily under a two-source condition, and compare it with MNE, dSPM, MxNE, LCMV, and RAP-MUSIC. Across 100 main-benchmark trials, QUBO achieved a mean cardinality-aware localization error of 8.45 mm, compared with 22.35 mm for MxNE, the best-performing baseline according to this metric, corresponding to a 62.2% reduction. The composite metric adds a 50 mm penalty per unit of source-count mismatch before normalization by the true source count. Because MxNE returned only one source in 35 trials, the reported reduction reflects both spatial localization and source-count performance. In separate sensitivity experiments, QUBO remained competitive across the tested sensor-noise and source-count conditions, although RAP-MUSIC performed comparably to or better than QUBO in some low-noise and three-source settings. The present experiments use classical simulated annealing and do not evaluate quantum hardware or claim quantum advantage. The resulting binary quadratic objective admits a direct Ising representation, enabling future evaluation on quantum-annealing and hybrid backends.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-08-18 in eess.SP).
Categorie arXiv: Signal Processing (eess.SP).
Pagina del lavoro: https://arxiv.org/abs/2608.14738 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-19T01:25:14.294Z dalla pagina https://arxiv.org/catchup/eess.SP/2026-08-18?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).