Metraipolis › archive › dc_5efe4fc082b4

Enhancing Grid Stability with Synchronverter-Based Control for Grid-Side Converters in Wind Power Systems — arXiv:2611.02976

Source
arXiv (en)
Original
https://arxiv.org/abs/2611.02976
License (as archived)
CC0-1.0
Archived
2026-11-03T11:54:50.076Z
SHA-256 of the archived text
571fb307d588bbc96fd4f895f717b6d4bed97d9b6d024e0f8c156fdfc4d59671
Stable URL of this page
https://metraipolis.com/documento/dc_5efe4fc082b4

How to cite

Enhancing Grid Stability with Synchronverter-Based Control for Grid-Side Converters in Wind Power Systems — arXiv:2611.02976 — arXiv (en), https://arxiv.org/abs/2611.02976 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_5efe4fc082b4 (Metraipolis archive dc_5efe4fc082b4, sha256 571fb307d588bbc96fd4f895f717b6d4bed97d9b6d024e0f8c156fdfc4d59671)
BibTeX
@misc{dc5efe4fc082b4,
  title = {Enhancing Grid Stability with Synchronverter-Based Control for Grid-Side Converters in Wind Power Systems — arXiv:2611.02976},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2611.02976},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_5efe4fc082b4; sha256 571fb307d588bbc96fd4f895f717b6d4bed97d9b6d024e0f8c156fdfc4d59671},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.02976. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

This paper proposes a new synchronverter control strategy for wind turbine grid-side converters, aimed at bolstering grid resilience by providing essential inertial frequency support without the need for additional energy storage components. The strategy harnesses the inherent energy storage capability of the DC-link capacitor to emulate the dynamic behavior of a synchronous generator, effectively contributing to grid inertia. A dual-controller architecture is implemented, consisting of a slow PI controller to maintain DC voltage stability and a fast protection mechanism to prevent overvoltage and undervoltage excursions. Critically, the control scheme facilitates controlled reductions of up to 10% in the DC-link voltage, generating a power reserve that can be strategically deployed for inertia emulation while preserving safe operating limits. The efficacy of the proposed method is validated through simulations of a representative three-turbine wind power plant, incorporating coordinated operation via virtual friction for inter-machine damping and local-global control strategies. Results showcase the superior performance of the proposed strategy compared to conventional grid-following control, emphasizing its potential to significantly improve grid stability and address the increasing challenges posed by high renewable energy penetration.

Tema degli esploratori: calcolo e infrastrutture (elenco arXiv eess.SY, nuovi lavori del giorno).
Categorie arXiv: Systems and Control (eess.SY).
Pagina del lavoro: https://arxiv.org/abs/2611.02976 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-03T11:15:22.680Z dalla pagina https://arxiv.org/list/eess.SY/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).