Metraipolis › archive › dc_5dc3ac179816
Respect Your Zero-Shot Uncertainty: Conservative Calibration for Test-Time-Adapted Vision-Language Models — arXiv:2608.05945
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.05945
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-31T10:36:24.691Z
- SHA-256 of the archived text
342c7535ea7b85de30ec7d5a697d2b51b7f7ae649685333488fb722b0512ae36- Stable URL of this page
https://metraipolis.com/documento/dc_5dc3ac179816
How to cite
Respect Your Zero-Shot Uncertainty: Conservative Calibration for Test-Time-Adapted Vision-Language Models — arXiv:2608.05945 — arXiv (en), https://arxiv.org/abs/2608.05945 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_5dc3ac179816 (Metraipolis archive dc_5dc3ac179816, sha256 342c7535ea7b85de30ec7d5a697d2b51b7f7ae649685333488fb722b0512ae36)
BibTeX
@misc{dc5dc3ac179816,
title = {Respect Your Zero-Shot Uncertainty: Conservative Calibration for Test-Time-Adapted Vision-Language Models — arXiv:2608.05945},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.05945},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_5dc3ac179816; sha256 342c7535ea7b85de30ec7d5a697d2b51b7f7ae649685333488fb722b0512ae36},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.05945. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Test-time adaptation (TTA) can improve the recognition accuracy of vision-language models under distribution shift, but often degrades calibration, making predictive confidence unreliable for downstream decision-making. Many existing label-free calibration approaches are either coupled to prompt optimization or rely on logit-range statistics that provide only a coarse characterization of the predictive distribution. We show that TTA can increase confidence and reduce entropy even when the top-1 prediction and its correctness remain unchanged, a failure mode we term prediction-preserving sharpening. Across diverse TTA methods and benchmarks, larger entropy reductions relative to paired zero-shot predictions are associated with greater increases in Expected Calibration Error (ECE). On entropy-reduced samples, confidence gains also tend to exceed accuracy gains. Based on these findings, we propose Zero-Shot-Anchored Entropy Calibration (ZAEC), a label-free post-hoc method that uses zero-shot entropy as a sample-specific uncertainty reference. ZAEC selectively restores the zero-shot entropy of sharpened predictions through minimal temperature scaling while leaving all other predictions unchanged. It requires no labeled calibration data or learned parameters and preserves class rankings and classification accuracy. Across five TTA methods and 15 datasets, ZAEC achieves the lowest post-hoc macro-average ECE on ViT-B/16, with consistent gains on RN50. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-08-07 in cs.CV). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2608.05945 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-31T10:23:31.037Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-08-07?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).