Metraipolis › archive › dc_5d7dcb350dd8

WebMRIQC: A Web-Based Implementation of MRIQC for Accessible MRI Image Quality Assessment in Resource-Constrained Settings — arXiv:2609.24014

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.24014
License (as archived)
CC0-1.0
Archived
2026-10-09T22:04:48.726Z
SHA-256 of the archived text
141f99a1bb89456305055219898f0b4e91fefa25f392caf3f008764eb716b57b
Stable URL of this page
https://metraipolis.com/documento/dc_5d7dcb350dd8

How to cite

WebMRIQC: A Web-Based Implementation of MRIQC for Accessible MRI Image Quality Assessment in Resource-Constrained Settings — arXiv:2609.24014 — arXiv (en), https://arxiv.org/abs/2609.24014 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_5d7dcb350dd8 (Metraipolis archive dc_5d7dcb350dd8, sha256 141f99a1bb89456305055219898f0b4e91fefa25f392caf3f008764eb716b57b)
BibTeX
@misc{dc5d7dcb350dd8,
  title = {WebMRIQC: A Web-Based Implementation of MRIQC for Accessible MRI Image Quality Assessment in Resource-Constrained Settings — arXiv:2609.24014},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.24014},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_5d7dcb350dd8; sha256 141f99a1bb89456305055219898f0b4e91fefa25f392caf3f008764eb716b57b},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.24014. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Reliable quality control (QC) of magnetic resonance imaging (MRI) is essential for reliable diagnostic neuroimaging, yet standard manual assessment is subjective and time-consuming. MRIQC has established standardized automated extraction of image-quality metrics (IQMs), but its reliance on local computational imaging skills and capacity including high-performance computing, limits its adoption in resource-constrained settings (RCS). We present WebMRIQC ( this http URL ), an open-source browser-based platform that wraps the validated MRIQC engine behind a zero-installation web interface. WebMRIQC automates the DICOM-to-BIDS conversion of de-identified MRI scans, executes the unmodified containerized MRIQC pipeline on a shared compute node governed by a fair-share job queue, and returns an interactive in-browser dashboard. The dashboard grounds every IQM in published quality thresholds, benchmarks each scan against the normative distribution of high-resource open datasets, and supports cross-site multicentre implementation of optimized scan protocols in this http URL describe the system architecture and a validation framework establishing measurement equivalence between WebMRIQC and native MRIQC across thirteen IQMs on the BraTS-Africa and BraTS 2021 datasets. Preliminary results indicate strong agreement for contrast-, signal and noise-based metrics, demonstrating that web-based implementation lowers the barrier to standardized MRI QC and provides a foundation for harmonized, regionally adapted quality benchmarks across RCS imaging sites. The code is publicly available here this https URL .

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-22 in cs.CV).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2609.24014 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-09T21:45:20.968Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-22?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).