Metraipolis › archive › dc_5c9aabd9785d
Noisy-Label Calibration with Multiple Unreliable Labels — arXiv:2610.19543
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2610.19543
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-15T14:23:25.962Z
- SHA-256 of the archived text
3efbd846b9f3001684f1f1b0ec42b6b2477f6faa495672512285729063b394ba- Stable URL of this page
https://metraipolis.com/documento/dc_5c9aabd9785d
How to cite
Noisy-Label Calibration with Multiple Unreliable Labels — arXiv:2610.19543 — arXiv (en), https://arxiv.org/abs/2610.19543 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_5c9aabd9785d (Metraipolis archive dc_5c9aabd9785d, sha256 3efbd846b9f3001684f1f1b0ec42b6b2477f6faa495672512285729063b394ba)
BibTeX
@misc{dc5c9aabd9785d,
title = {Noisy-Label Calibration with Multiple Unreliable Labels — arXiv:2610.19543},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2610.19543},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_5c9aabd9785d; sha256 3efbd846b9f3001684f1f1b0ec42b6b2477f6faa495672512285729063b394ba},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.19543. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
In medical annotation and crowdsourcing, multiple annotators assign labels to each example, but these labels may be incorrect. Treating such noisy labels as ground truth can bias calibration evaluation. To address this problem, we propose methods for evaluating and recalibrating a fixed binary predictor under the underlying clean-label distribution, using only noisy annotations. First, given annotator-specific noise probabilities, we propose Noise Corrected ECE (NC-ECE), a binned estimator of expected calibration error (ECE) under class-conditional noise. We derive non-asymptotic bounds on the estimator's bias. Then, we propose practical algorithms for estimating unknown noise probabilities under conditional independence and label-orientation assumptions. We also develop loss-based and histogram post-hoc recalibration with clean-risk and calibration guarantees, respectively. Experiments on semi-synthetic benchmarks show that the proposed ECE estimator closely tracks its clean-label oracle counterpart and that the recalibration methods substantially improve latent-label calibration, whereas uncorrected recalibration against noisy annotations can degrade it. Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.LG, nuovi lavori del giorno). Categorie arXiv: Machine Learning (stat.ML) ; Machine Learning (cs.LG). Pagina del lavoro: https://arxiv.org/abs/2610.19543 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-15T13:53:35.869Z dalla pagina https://arxiv.org/list/cs.LG/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).