Metraipolis › archive › dc_5af3f7fbd3da

Forbidden Region Dynamic Active Constraints in Robot-Assisted Minimally Invasive Surgery — arXiv:2608.03010

Source
arXiv (en)
Original
https://arxiv.org/abs/2608.03010
License (as archived)
CC0-1.0
Archived
2026-10-31T13:07:50.390Z
SHA-256 of the archived text
2441a83e74914421fc5a7dfd60358cc4bcbfbe632310bc29afc653b21c3c7134
Stable URL of this page
https://metraipolis.com/documento/dc_5af3f7fbd3da

How to cite

Forbidden Region Dynamic Active Constraints in Robot-Assisted Minimally Invasive Surgery — arXiv:2608.03010 — arXiv (en), https://arxiv.org/abs/2608.03010 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_5af3f7fbd3da (Metraipolis archive dc_5af3f7fbd3da, sha256 2441a83e74914421fc5a7dfd60358cc4bcbfbe632310bc29afc653b21c3c7134)
BibTeX
@misc{dc5af3f7fbd3da,
  title = {Forbidden Region Dynamic Active Constraints in Robot-Assisted Minimally Invasive Surgery — arXiv:2608.03010},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2608.03010},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_5af3f7fbd3da; sha256 2441a83e74914421fc5a7dfd60358cc4bcbfbe632310bc29afc653b21c3c7134},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.03010. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

In robot-assisted surgery, Forbidden Region Active Constraints (FRAC) represent a control strategy that helps maintain task safety by generating anisotropic haptic guidance to surgeons. However, several challenges need to be overcome before FRAC can benefit teleoperative surgery in a clinical setting. These challenges include the ability to allow for dynamic tissue deformation, maintain energetic passivity, and speed of implementation, among others. In this study, we propose the pipeline design for an energy dissipative FRAC strategy, which accommodates the dynamic tissue deformation caused by respiratory movements, by utilizing a depth sensing camera. The proposed FRAC strategy adopts a fine mesh representation, with a total number of 122,806 polygons in the case study presented, while running at 43.48Hz. We designed in vitro trajectory tracking experiments conducted by a "virtual" surgeon to aid quantitative assessment of the method, including its effectiveness in maintaining task safety, which was confirmed by successfully maintaining a pre-defined safety distance across all trials. We also conducted comparative studies to investigate the robustness and time-efficiency of our method against other FRAC methods that rely on simple geometry AC representations. We demonstrate that our method provides a more robust and effective guidance overall, while maintaining comparable, if not lower, time costs.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-08-05 in cs.RO).
Categorie arXiv: Robotics (cs.RO).
Pagina del lavoro: https://arxiv.org/abs/2608.03010 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-31T12:55:56.548Z dalla pagina https://arxiv.org/catchup/cs.RO/2026-08-05?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).