Metraipolis › archive › dc_5a150a4dedc1

Metabolic multireactor: Practical considerations for using simple oxygen sensing optodes for high-throughput batch reactor metabolism experiments — Europe PMC PMID:37432946

Source
Europe PMC (en)
Original
https://europepmc.org/article/MED/37432946
DOI
10.1371/journal.pone.0284256
License (as archived)
CC0-1.0
Archived
2026-10-07T12:57:58.978Z
SHA-256 of the archived text
6a2947f0b76bd3c8b343c6c72af309eee510fe3f382def9ecbe02788dac6d98d
Stable URL of this page
https://metraipolis.com/documento/dc_5a150a4dedc1

How to cite

Metabolic multireactor: Practical considerations for using simple oxygen sensing optodes for high-throughput batch reactor metabolism experiments — Europe PMC PMID:37432946 — Europe PMC (en), https://europepmc.org/article/MED/37432946 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_5a150a4dedc1 (Metraipolis archive dc_5a150a4dedc1, sha256 6a2947f0b76bd3c8b343c6c72af309eee510fe3f382def9ecbe02788dac6d98d)
BibTeX
@misc{dc5a150a4dedc1,
  title = {Metabolic multireactor: Practical considerations for using simple oxygen sensing optodes for high-throughput batch reactor metabolism experiments — Europe PMC PMID:37432946},
  howpublished = {Europe PMC (en)},
  url = {https://europepmc.org/article/MED/37432946},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_5a150a4dedc1; sha256 6a2947f0b76bd3c8b343c6c72af309eee510fe3f382def9ecbe02788dac6d98d},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: Europe PMC (en), https://europepmc.org/article/MED/37432946. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

We present a system for carrying out small batch reactor oxygen consumption experiments on water and sediment samples for environmental questions. In general, it provides several advantages that can help researchers achieve impactful experiments at relatively low costs and high data quality. In particular, it allows for multiple reactors to be operated and their oxygen concentrations to be measured simultaneously, providing high throughput and high time-resolution data, which can be advantageous. Most existing literature on similar small batch-reactor metabolic studies is limited to either only a few samples, or only a few time points per sample, which can restrict the ability for researchers to learn from their experiments. The oxygen sensing system is based very directly on the work of Larsen, et al. [2011], and similar oxygen sensing technology is widely used in the literature. As such we do not delve deeply into the specifics of the fluorescent dye sensing mechanism. Instead, we focus on practical considerations. We describe the construction and operation of the calibration and experimental systems, and answer many of the questions likely to come up when other researchers choose to build and operate a similar system themselves (questions we ourselves had when we first built the system). In this way, we hope to provide an approachable and easy to use research article that can help other researchers construct and operate a similar system that can be tailored to ask their own research questions, with a minimum of confusion and missteps along the way.

Tema degli esploratori: scibile generale (retro-catalogo completo della fonte, senza filtro di tema) (retro-catalogo: tutto il sottoinsieme open access di Europe PMC con licenza libera).
Pubblicazione: PloS one, 2023 (prima pubblicazione 2023-07-11).
Identificativi: PMID 37432946 · PMCID PMC10335663 · DOI 10.1371/journal.pone.0284256.
Descrittori MeSH principali: Confusion; Oxygen Consumption.
Pagina: https://europepmc.org/article/MED/37432946 — https://doi.org/10.1371/journal.pone.0284256. Autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza dell'articolo dichiarata da Europe PMC: CC0 (la versione è indicata dall'editore sulla pagina). Abstract riportato senza modifiche al contenuto, con attribuzione; deposito marcato CC0.
Letto il 2026-10-07T12:28:09.618Z tramite l'API REST ufficiale di Europe PMC (EMBL-EBI), nel rispetto del robots.txt e del crawl-delay.