Metraipolis › archive › dc_598d7153a48a
A Physics-Based Closed-Loop Robotic Bioprinting Framework Towards Volumetric Muscle Loss Treatment — arXiv:2609.12159
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.12159
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-16T03:58:06.255Z
- SHA-256 of the archived text
7d74bd5d074bc2d7ae3d35daba760700540d67e9a4cbde8900d1af11e684f690- Stable URL of this page
https://metraipolis.com/documento/dc_598d7153a48a
How to cite
A Physics-Based Closed-Loop Robotic Bioprinting Framework Towards Volumetric Muscle Loss Treatment — arXiv:2609.12159 — arXiv (en), https://arxiv.org/abs/2609.12159 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_598d7153a48a (Metraipolis archive dc_598d7153a48a, sha256 7d74bd5d074bc2d7ae3d35daba760700540d67e9a4cbde8900d1af11e684f690)
BibTeX
@misc{dc598d7153a48a,
title = {A Physics-Based Closed-Loop Robotic Bioprinting Framework Towards Volumetric Muscle Loss Treatment — arXiv:2609.12159},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.12159},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_598d7153a48a; sha256 7d74bd5d074bc2d7ae3d35daba760700540d67e9a4cbde8900d1af11e684f690},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.12159. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Robotic bioprinting and Direct Ink Writing (DIW) are being explored towards the treatment of Volumetric Muscle Loss (VML). While previous studies have shown the importance of proper parameter selection on the print outcome, existing approaches often rely on time- and material-intensive design of experiments methods, or require large, well-curated datasets for training machine learning models. In this paper, we propose a physics-based closed-loop robotic bioprinting system capable of near real-time parameter adaptation. The system integrates a 3D point cloud camera and fully autonomous vision-based algorithms to provide quantitative evaluation of printed constructs. This evaluation is fed into a controller that adjusts printing parameters to achieve a desired bead thickness. To assess the framework's performance, four experimental configurations were tested, each repeated three times. In these tests, printing began from an arbitrary initial parameter value, and the controller was tasked with adjusting the parameters to reach the desired thickness. The system converged in all trials, achieving a tracking error below 0.5 mm within an average of 5.2 seconds from the start of printing. The low standard deviation of the converged pressure over different tests (0.04 bar on average) demonstrates robustness and repeatability. Additional experiments were conducted with the controller turned off, enabling direct comparison with open-loop DIW bioprinting, further confirming the effectiveness of the proposed closed-loop framework in achieving the desired bead geometry. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-14 in cs.RO). Categorie arXiv: Robotics (cs.RO). Pagina del lavoro: https://arxiv.org/abs/2609.12159 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-16T03:44:44.692Z dalla pagina https://arxiv.org/catchup/cs.RO/2026-09-14?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).