Metraipolis › archive › dc_587a67a0da40
Oracle headroom without signal: null-calibrated evaluation of candidate selection for thermal heart rate estimation — arXiv:2610.02561
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2610.02561
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-06T09:06:49.944Z
- SHA-256 of the archived text
c4c36b964977e151b282c20d263ade3d8f06431b170d77f66c0a502c3c6360e0- Stable URL of this page
https://metraipolis.com/documento/dc_587a67a0da40
How to cite
Oracle headroom without signal: null-calibrated evaluation of candidate selection for thermal heart rate estimation — arXiv:2610.02561 — arXiv (en), https://arxiv.org/abs/2610.02561 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_587a67a0da40 (Metraipolis archive dc_587a67a0da40, sha256 c4c36b964977e151b282c20d263ade3d8f06431b170d77f66c0a502c3c6360e0)
BibTeX
@misc{dc587a67a0da40,
title = {Oracle headroom without signal: null-calibrated evaluation of candidate selection for thermal heart rate estimation — arXiv:2610.02561},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2610.02561},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_587a67a0da40; sha256 c4c36b964977e151b282c20d263ade3d8f06431b170d77f66c0a502c3c6360e0},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.02561. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Camera-based physiological monitoring can produce multiple estimates from several facial regions, extraction methods, and processing settings. Signal quality indices aim to select reliable estimates without a physiological reference, and their potential is often assessed with an oracle that selects the estimate closest to the reference in each window. This retrospective selection can reward chance agreement. We model the effect with order statistics. For K independent candidates unrelated to the reference, the expected oracle error decreases approximately as 1/K. We analyze thermal heart rate estimation on 96 iBVP recordings with 168 candidates per 10 s window. The oracle achieves a mean absolute error of 0.91 bpm, compared with 10.74 bpm for the best fixed configuration, 18.03 bpm for the best quality index, and 8.61 bpm for a constant predictor. With K = 24, a forehead signal from another recording matches the correct one, with 4.62 against 4.61 bpm. Oracle evaluations should report candidate count, valid coverage, and matched null controls. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-10-05 in cs.CV). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2610.02561 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-06T08:21:44.152Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-10-05?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).