Metraipolis › archive › dc_585f1d44005c

Spatially Gated Diffusion for Localized Counterfactual Chest Radiograph Editing — arXiv:2610.00805

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.00805
License (as archived)
CC0-1.0
Archived
2026-10-06T19:16:29.610Z
SHA-256 of the archived text
32955d1172652313537b4dae9ad6a020f62125a2d398eb16afbd36f068cf4888
Stable URL of this page
https://metraipolis.com/documento/dc_585f1d44005c

How to cite

Spatially Gated Diffusion for Localized Counterfactual Chest Radiograph Editing — arXiv:2610.00805 — arXiv (en), https://arxiv.org/abs/2610.00805 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_585f1d44005c (Metraipolis archive dc_585f1d44005c, sha256 32955d1172652313537b4dae9ad6a020f62125a2d398eb16afbd36f068cf4888)
BibTeX
@misc{dc585f1d44005c,
  title = {Spatially Gated Diffusion for Localized Counterfactual Chest Radiograph Editing — arXiv:2610.00805},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.00805},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_585f1d44005c; sha256 32955d1172652313537b4dae9ad6a020f62125a2d398eb16afbd36f068cf4888},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.00805. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Editing a chest radiograph requires completing the requested change while preserving unrelated content. We study a latent diffusion editor with an instruction-independent source trajectory and an instruction-conditioned editing trajectory. A learned gate mixes their post-sampler candidates at each executed step, and a separate image-space mask composites the decoded proposal with the source. On 2,400 MIMIC-derived requests, 2,244 outputs met the joint target, preservation, quality, and coverage rubric (93.5%), and target completion was 97.4%. Joint validity exceeded a matched composition-only control by 1.7 percentage points (paired patient-cluster 95% interval, 0.6--2.8). At a fixed learned mask, the learned-gate proposal improved joint validity by 1.6 points (0.8--2.4); at a fixed learned proposal, the learned mask improved it by 2.6 points (1.7--3.5). Across three training seeds, mean joint validity was 93.5% with a 0.3-point sample standard deviation. A blinded 240-request assessment yielded adjudicated joint validity of 93.3% for the full editor and 91.7% for composition only. Protected-region mean absolute error decreased from 0.0190 in the raw proposal to 0.0075 after composition. These findings distinguish recurrent-gating effects on the proposal from preservation through final composition in the assessed cohort.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-10-02 in cs.CV).
Categorie arXiv: Image and Video Processing (eess.IV) ; Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2610.00805 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-06T17:37:36.930Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-10-02?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).