Metraipolis › archive › dc_576b87d7b85e
Braided endovascular implants for intracranial aneurysms: mechanics, hemodynamics, and clinical translation — arXiv:2609.18544
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.18544
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-15T17:57:01.041Z
- SHA-256 of the archived text
ff1564f8264fc2f3786b283abdf6e2dc969092ac28847216dd7e0693e9fc3179- Stable URL of this page
https://metraipolis.com/documento/dc_576b87d7b85e
How to cite
Braided endovascular implants for intracranial aneurysms: mechanics, hemodynamics, and clinical translation — arXiv:2609.18544 — arXiv (en), https://arxiv.org/abs/2609.18544 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_576b87d7b85e (Metraipolis archive dc_576b87d7b85e, sha256 ff1564f8264fc2f3786b283abdf6e2dc969092ac28847216dd7e0693e9fc3179)
BibTeX
@misc{dc576b87d7b85e,
title = {Braided endovascular implants for intracranial aneurysms: mechanics, hemodynamics, and clinical translation — arXiv:2609.18544},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.18544},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_576b87d7b85e; sha256 ff1564f8264fc2f3786b283abdf6e2dc969092ac28847216dd7e0693e9fc3179},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.18544. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Endovascular implants prevent intracranial aneurysm rupture by altering the mechanical and hemodynamic environment at the aneurysm neck. Yet many in silico workflows prescribe or reconstruct the post-deployment geometry before computing flow, leaving unresolved the mechanics that create the clinically relevant interface. Here we review braided intraluminal flow diverters, intrasaccular devices, and emerging flow-disruption concepts across deployment mechanics, inter-wire and wire-wall contact, superelasticity, wall apposition, pore geometry, computational fluid dynamics, and fluid-structure interaction. We connect these modeling choices to neck coverage, malapposition, migration, deformation, and durability, and distinguish established evidence from mechanistic inference and prospective hypotheses. We argue that model fidelity should match the clinical question: prescribed or fast placement may support screening, whereas questions of coverage, apposition, compaction, and migration benefit from mechanically plausible deployment states. An interface-resolved mechanics-to-flow framework, supported by measurable validation targets and standardized reporting, could improve device design and enable more reliable patient-specific treatment planning. Tema degli esploratori: fisica e astronomia (retro-catalogo arXiv: annunci del 2026-09-17 in physics.comp-ph). Categorie arXiv: Computational Physics (physics.comp-ph) ; Applied Physics (physics.app-ph); Biological Physics (physics.bio-ph); Fluid Dynamics (physics.flu-dyn). Pagina del lavoro: https://arxiv.org/abs/2609.18544 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-15T17:06:32.270Z dalla pagina https://arxiv.org/catchup/physics.comp-ph/2026-09-17?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).