Metraipolis › archive › dc_56b8e8d4fd8a
A Tale of Two Calibrators: Comparing Newtonian and Photon Calibration in Advanced LIGO after the Third Observing Run — arXiv:2609.01917
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.01917
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-17T06:21:34.369Z
- SHA-256 of the archived text
7cf4f1be978200f30eb464751685e3934af7fe67499577aafb81b0c91a99b7b6- Stable URL of this page
https://metraipolis.com/documento/dc_56b8e8d4fd8a
How to cite
A Tale of Two Calibrators: Comparing Newtonian and Photon Calibration in Advanced LIGO after the Third Observing Run — arXiv:2609.01917 — arXiv (en), https://arxiv.org/abs/2609.01917 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_56b8e8d4fd8a (Metraipolis archive dc_56b8e8d4fd8a, sha256 7cf4f1be978200f30eb464751685e3934af7fe67499577aafb81b0c91a99b7b6)
BibTeX
@misc{dc56b8e8d4fd8a,
title = {A Tale of Two Calibrators: Comparing Newtonian and Photon Calibration in Advanced LIGO after the Third Observing Run — arXiv:2609.01917},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.01917},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_56b8e8d4fd8a; sha256 7cf4f1be978200f30eb464751685e3934af7fe67499577aafb81b0c91a99b7b6},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.01917. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Precise calibration of LIGO's strain readout plays a vital role in our ability to extract information from gravitational-wave detections. We present a comparative analysis of two independent direct-force calibration methods: the Newtonian Calibrator (NCal) and Photon Calibrator (PCal) systems. Currently, LIGO relies solely on the PCal system as its absolute calibration reference. To facilitate comparison, a series of direct-force injections were performed using the NCal and PCal systems at the LIGO Hanford observatory just after the completion of the third observing run. We compute the ratio of the measured to expected strain amplitudes for every injection. For each injection frequency across a 30 Hz band, the ratios of NCal and PCal differ by $\sim$0.5-1%, demonstrating a small systematic difference between the two systems. This offset highlights the importance of maintaining multiple independent calibration references to validate LIGO's calibration. Tema degli esploratori: fisica e astronomia (retro-catalogo arXiv: annunci del 2026-09-03 in gr-qc). Categorie arXiv: General Relativity and Quantum Cosmology (gr-qc). Pagina del lavoro: https://arxiv.org/abs/2609.01917 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-17T05:57:23.642Z dalla pagina https://arxiv.org/catchup/gr-qc/2026-09-03?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).