Metraipolis › archive › dc_5664724ad4e6

A$^3$PreCore: Robust Rigid Registration for Native FLAIR-Space Brain-Mask Transfer — arXiv:2610.20561

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.20561
License (as archived)
CC0-1.0
Archived
2026-10-15T15:04:03.962Z
SHA-256 of the archived text
f64a8e7c3b60128e29a3b733a90486c4b5d7b9d6139a5f64d77cfdd7996d9787
Stable URL of this page
https://metraipolis.com/documento/dc_5664724ad4e6

How to cite

A$^3$PreCore: Robust Rigid Registration for Native FLAIR-Space Brain-Mask Transfer — arXiv:2610.20561 — arXiv (en), https://arxiv.org/abs/2610.20561 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_5664724ad4e6 (Metraipolis archive dc_5664724ad4e6, sha256 f64a8e7c3b60128e29a3b733a90486c4b5d7b9d6139a5f64d77cfdd7996d9787)
BibTeX
@misc{dc5664724ad4e6,
  title = {A$^3$PreCore: Robust Rigid Registration for Native FLAIR-Space Brain-Mask Transfer — arXiv:2610.20561},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.20561},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_5664724ad4e6; sha256 f64a8e7c3b60128e29a3b733a90486c4b5d7b9d6139a5f64d77cfdd7996d9787},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.20561. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Reliable brain-mask transfer into native fluid-attenuated inversion recovery (FLAIR) space can fail when T1-to-FLAIR rigid registration is unstable. We developed A$^3$PreCore, a six-degree-of-freedom rigid-registration strategy that aligns the full bias-corrected T1-weighted image to native FLAIR using normalized mutual information while preserving the established T1-space anatomical mask. We also introduced extended quantitative quality control (E-QC), which characterizes mask extent, field-of-view-relative position, FLAIR intensity support, boundary support, inferior morphology, and pairwise geometric disagreement. In 78 participants with paired T1-weighted and FLAIR imaging, A$^3$PreCore was compared with fsl_anat and the Brain Extraction Tool (BET). Gross rigid-body misregistration occurred in 21/78 fsl_anat outputs (26.9%) and 0/78 A$^3$PreCore outputs (exact two-sided McNemar p=9.54 x 10^-7). Among 57 participants without gross fsl_anat misregistration, A$^3$PreCore preserved close agreement (median Dice=0.993; median paired Delta NMI=-0.00007, p=0.429). A$^3$PreCore remained broadly concordant with BET (median Dice=0.955), with less inferior and extracranial extension in representative comparisons. Method-blinded neuroscientists ranked A$^3$PreCore first in 35/40 participants (87.5%). E-QC additionally exposed severe orientation-related disagreement not evident from global descriptors or centroid displacement alone. These findings support A$^3$PreCore as a robust native-FLAIR brain-mask transfer strategy and E-QC as a complementary framework for multidimensional mask characterization and participant-specific geometric quality control.

Tema degli esploratori: statistica e scienza dei dati (elenco arXiv eess.IV, nuovi lavori del giorno).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV) ; Image and Video Processing (eess.IV).
Pagina del lavoro: https://arxiv.org/abs/2610.20561 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-15T14:07:53.880Z dalla pagina https://arxiv.org/list/eess.IV/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).