Metraipolis › archive › dc_56521e730eab
Pediatric ECG foundation model via adult-to-pediatric fine-tuning: downstream tasks and clinical evaluation — arXiv:2611.07717
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2611.07717
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-06T14:41:43.906Z
- SHA-256 of the archived text
c18e0cd330b879ccb9295d0cdb45d45509bac1d6ad55b5b5dd061176b42cbdb8- Stable URL of this page
https://metraipolis.com/documento/dc_56521e730eab
How to cite
Pediatric ECG foundation model via adult-to-pediatric fine-tuning: downstream tasks and clinical evaluation — arXiv:2611.07717 — arXiv (en), https://arxiv.org/abs/2611.07717 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_56521e730eab (Metraipolis archive dc_56521e730eab, sha256 c18e0cd330b879ccb9295d0cdb45d45509bac1d6ad55b5b5dd061176b42cbdb8)
BibTeX
@misc{dc56521e730eab,
title = {Pediatric ECG foundation model via adult-to-pediatric fine-tuning: downstream tasks and clinical evaluation — arXiv:2611.07717},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2611.07717},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_56521e730eab; sha256 c18e0cd330b879ccb9295d0cdb45d45509bac1d6ad55b5b5dd061176b42cbdb8},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.07717. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Pediatric electrocardiogram (ECG) interpretation is complicated by age-dependent electrophysiological changes that limit direct transfer of adult AI models. We asked whether an adult ECG foundation model could be adapted to pediatric ECGs. Using 339,563 12-lead ECGs from 238,189 children, we compared direct application, pediatric fine-tuning, and training from scratch under an identical architecture. Direct transfer was poor (mean AUC 0.8256). Fine-tuning reached 0.9695, above de novo training (0.9661), and attained 0.9079 using only 1% of training data. On 10,999 external ECGs, fine-tuning achieved a mean AUC of 0.9385 across 30 labels. It generalized to age regression (MAE 1.12 years) and congenital heart disease classification (AUC 0.9562). Across 17 clinicians and 100 cases, diagnostic accuracy rose from 56.8% to 65.4% (p < 0.001) and did not decline when AI erred. Adult ECG foundation models require pediatric adaptation; fine-tuning offers a data-efficient route to scalable pediatric ECG AI. Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.AI, nuovi lavori del giorno). Categorie arXiv: Artificial Intelligence (cs.AI). Pagina del lavoro: https://arxiv.org/abs/2611.07717 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-11-06T14:18:42.645Z dalla pagina https://arxiv.org/list/cs.AI/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).