Metraipolis › archive › dc_55df13377d96
Capstan-driven Continuum Surgical Robot: Design, Modeling, and Perception — arXiv:2608.13396
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.13396
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-19T04:56:32.696Z
- SHA-256 of the archived text
294f842b41fbe1c5d24685aa723a7bc39bc6bdaa527959a2370efc00323c77e3- Stable URL of this page
https://metraipolis.com/documento/dc_55df13377d96
How to cite
Capstan-driven Continuum Surgical Robot: Design, Modeling, and Perception — arXiv:2608.13396 — arXiv (en), https://arxiv.org/abs/2608.13396 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_55df13377d96 (Metraipolis archive dc_55df13377d96, sha256 294f842b41fbe1c5d24685aa723a7bc39bc6bdaa527959a2370efc00323c77e3)
BibTeX
@misc{dc55df13377d96,
title = {Capstan-driven Continuum Surgical Robot: Design, Modeling, and Perception — arXiv:2608.13396},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.13396},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_55df13377d96; sha256 294f842b41fbe1c5d24685aa723a7bc39bc6bdaa527959a2370efc00323c77e3},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.13396. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Shape and force sensing have long been critical bottlenecks in the development of compact capstan-driven continuum surgical robots, primarily due to the difficulty of obtaining cable tension information within the confined capstan assembly. To overcome these challenges, this paper presents an integrated design-modeling-sensing approach based on the concept of actuation-perception co-design. A compliant element is introduced into the motor mounting bracket of the drive system, enabling micro-deformation under the cable reaction force and thereby allowing real-time cable tension measurement without occupying the compact capstan space. To address the modeling complexity arising from unconventional joint configurations introduced by the spatial cable routing strategy, a parallel computation framework based on a multibody short-thick-beam model is proposed, which captures shear effects in short beam segments and synergistic multi-cable interactions while achieving real-time performance. Building on this framework, stable shape and force sensing is achieved by incorporating a proximal multi-axis force/torque sensor as an additional measurement anchor. Following this design-modeling-sensing framework, capstan-driven continuum surgical robots with single- and dual-segment configurations are developed. Experimental results validate the proposed framework in both single- and dual-segment continuum robots, demonstrating real-time tip pose estimation together with contact force and location perception. By enabling cable tension feedback without compromising the compact capstan architecture, the proposed framework makes integrated perception feasible for capstan-driven continuum surgical robots. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-08-14 in cs.RO). Categorie arXiv: Robotics (cs.RO). Pagina del lavoro: https://arxiv.org/abs/2608.13396 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-19T04:47:48.664Z dalla pagina https://arxiv.org/catchup/cs.RO/2026-08-14?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).