Metraipolis › archive › dc_559d79d5b108
Closed-Form Optimal Weight Splitting for Matrix-Vector Multiply on Noisy In-Memory Accelerators — arXiv:2610.20359
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2610.20359
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-15T14:43:15.191Z
- SHA-256 of the archived text
9c7564a6c66879593107db6ac72a23089cb8abcdf47cf5f632655652ea71fcf9- Stable URL of this page
https://metraipolis.com/documento/dc_559d79d5b108
How to cite
Closed-Form Optimal Weight Splitting for Matrix-Vector Multiply on Noisy In-Memory Accelerators — arXiv:2610.20359 — arXiv (en), https://arxiv.org/abs/2610.20359 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_559d79d5b108 (Metraipolis archive dc_559d79d5b108, sha256 9c7564a6c66879593107db6ac72a23089cb8abcdf47cf5f632655652ea71fcf9)
BibTeX
@misc{dc559d79d5b108,
title = {Closed-Form Optimal Weight Splitting for Matrix-Vector Multiply on Noisy In-Memory Accelerators — arXiv:2610.20359},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2610.20359},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_559d79d5b108; sha256 9c7564a6c66879593107db6ac72a23089cb8abcdf47cf5f632655652ea71fcf9},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.20359. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Analog in-memory computing performs the matrix-vector multiplications of neural networks directly inside the memory array, which saves time and energy. But each memory cell stores only a few levels and is noisy, so one cell cannot hold a weight precisely. The standard fix is to split each weight across several cells, like digits of a number. The base of this split decides the trade-off: a large base gives fine resolution but amplifies the noise, and a base near one averages the noise but wastes resolution. The best-known prior analysis considers only the noise, and so it always picks a base of one. We propose a principled method that also accounts for the limited number of levels per cell. It gives the optimal base in closed form, from a single measurement of the device noise. On a device-physics simulator, the optimal split is 3.3 dB more accurate than the common base-16 split, and it beats equal splitting in end-application accuracy. Tema degli esploratori: calcolo e infrastrutture (elenco arXiv cs.ET, nuovi lavori del giorno). Categorie arXiv: Emerging Technologies (cs.ET). Pagina del lavoro: https://arxiv.org/abs/2610.20359 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-15T14:00:53.775Z dalla pagina https://arxiv.org/list/cs.ET/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).