Metraipolis › archive › dc_555058ee9688
Retention-Constrained Post-Training Quantization of Cellpose-SAM for Stem Cell Microscopy — arXiv:2609.21038
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.21038
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-10T02:52:13.391Z
- SHA-256 of the archived text
bcc16c8d595decebce4c3cb13f59725a0a5c61b0210d95d0faf1817c8ea68215- Stable URL of this page
https://metraipolis.com/documento/dc_555058ee9688
How to cite
Retention-Constrained Post-Training Quantization of Cellpose-SAM for Stem Cell Microscopy — arXiv:2609.21038 — arXiv (en), https://arxiv.org/abs/2609.21038 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_555058ee9688 (Metraipolis archive dc_555058ee9688, sha256 bcc16c8d595decebce4c3cb13f59725a0a5c61b0210d95d0faf1817c8ea68215)
BibTeX
@misc{dc555058ee9688,
title = {Retention-Constrained Post-Training Quantization of Cellpose-SAM for Stem Cell Microscopy — arXiv:2609.21038},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.21038},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_555058ee9688; sha256 bcc16c8d595decebce4c3cb13f59725a0a5c61b0210d95d0faf1817c8ea68215},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.21038. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Induced pluripotent stem cell (iPSC) culture increasingly relies on segmentation foundation models, yet deployment on laboratory CPUs and edge hardware requires compression schemes that are both efficient and auditable. We present a deployment-oriented evaluation of compressed Cellpose-SAM using a pre-specified retention criterion: the 95% cluster-bootstrap interval of mean change from FP32 must remain above a fixed -0.02 margin for every imaging modality. On a stratified 176-field panel spanning BBBC038 nuclei, BBBC039 U2OS fluorescence, and NIST iPSC images across density regimes, weight-only W8A16 preserves instance F1 across all modalities. A sensitivity-guided mixed W4/W8 scheme, using four INT8 exceptions, achieves a 6.76x reduction in weight storage with no observed catastrophic failures (0/176 fields), matching W8A16 at this sample size. In contrast, ternary weight-only quantization achieves 12.08x compression but fails catastrophically on 169/176 fields. These results demonstrate that compression should be evaluated by modality-stratified downstream retention rather than single-number accuracy, and establish a reproducible protocol for auditing compressed foundation models in regulated stem-cell imaging. Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-09-21 in cs.ET). Categorie arXiv: Medical Physics (physics.med-ph) ; Emerging Technologies (cs.ET); Quantitative Methods (q-bio.QM). Pagina del lavoro: https://arxiv.org/abs/2609.21038 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-10T02:30:57.333Z dalla pagina https://arxiv.org/catchup/cs.ET/2026-09-21?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).