Metraipolis › archive › dc_552d6e7684ac

A Few Cases Are All You Need: An Empirical Study of Annotation-Efficient LoRA Fine-Tuning of MedSAM3 — arXiv:2608.18731

Source
arXiv (en)
Original
https://arxiv.org/abs/2608.18731
License (as archived)
CC0-1.0
Archived
2026-10-18T13:45:19.502Z
SHA-256 of the archived text
e1372a9f554246b5c82a9257b2c952642052a33d603f7dcaa6211613bc15f6e7
Stable URL of this page
https://metraipolis.com/documento/dc_552d6e7684ac

How to cite

A Few Cases Are All You Need: An Empirical Study of Annotation-Efficient LoRA Fine-Tuning of MedSAM3 — arXiv:2608.18731 — arXiv (en), https://arxiv.org/abs/2608.18731 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_552d6e7684ac (Metraipolis archive dc_552d6e7684ac, sha256 e1372a9f554246b5c82a9257b2c952642052a33d603f7dcaa6211613bc15f6e7)
BibTeX
@misc{dc552d6e7684ac,
  title = {A Few Cases Are All You Need: An Empirical Study of Annotation-Efficient LoRA Fine-Tuning of MedSAM3 — arXiv:2608.18731},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2608.18731},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_552d6e7684ac; sha256 e1372a9f554246b5c82a9257b2c952642052a33d603f7dcaa6211613bc15f6e7},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.18731. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Medical image segmentation is essential for clinical workflows such as treatment planning and disease assessment. While specialist tools like TotalSegmentator and MRSegmentator achieve strong performance, they require large annotated datasets for training. Medical foundation models offer a promising alternative through large-scale pretraining that reduces the annotation burden for new tasks, but zero-shot performance remains limited. Parameter-efficient adaptation via Low-Rank Adaptation (LoRA) enables efficient specialization with few trainable parameters, but a key question remains: how many expert-annotated cases are needed to achieve clinically useful segmentation performance? We address this by adapting MedSAM3 with LoRA for five abdominal organs (liver, kidneys, spleen, gallbladder, and pancreas) in CT and MRI using only 1, 2, 5, and 10 annotated cases, evaluating on AMOS22 dataset. With just 10 cases, models achieve performance competitive with specialist systems trained on orders of magnitude more data. Notably, this includes reliable gallbladder segmentation (Dice 0.68 CT, 0.59 MRI) where existing tools fail almost completely (Dice 0.0004), while remaining within 5--10% of MRSegmentator for liver, kidneys, and spleen using over 100 times fewer annotations. Furthermore, external validation on the Whole Heart Segmentation dataset shows that the approach extends to cardiac segmentation, a use case beyond the scope of TotalSegmentator (MRI) and MRSegmentator, achieving competitive left ventricle (LV) performance with only 10 annotated cases. Training requires only3--5,hours per organ on a single GPU, approximately 2--3 times faster than nnU-Net. These findings suggest that ten annotated cases are sufficient for clinically useful segmentation, effectively reducing bottlenecks for both image annotation and training time.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-08-20 in cs.AI).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV) ; Artificial Intelligence (cs.AI).
Pagina del lavoro: https://arxiv.org/abs/2608.18731 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-18T13:41:17.970Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-08-20?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).