Metraipolis › archive › dc_53beeb0b1f2c

UnCapsTSR: An Unsupervised Transformer-based Image Super-Resolution Approach for Capsule Endoscopy Images — arXiv:2609.02476

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.02476
License (as archived)
CC0-1.0
Archived
2026-10-17T05:50:06.970Z
SHA-256 of the archived text
94148efe290a86178c6544714682fc3644cd6061d5596fadb594934156962f54
Stable URL of this page
https://metraipolis.com/documento/dc_53beeb0b1f2c

How to cite

UnCapsTSR: An Unsupervised Transformer-based Image Super-Resolution Approach for Capsule Endoscopy Images — arXiv:2609.02476 — arXiv (en), https://arxiv.org/abs/2609.02476 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_53beeb0b1f2c (Metraipolis archive dc_53beeb0b1f2c, sha256 94148efe290a86178c6544714682fc3644cd6061d5596fadb594934156962f54)
BibTeX
@misc{dc53beeb0b1f2c,
  title = {UnCapsTSR: An Unsupervised Transformer-based Image Super-Resolution Approach for Capsule Endoscopy Images — arXiv:2609.02476},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.02476},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_53beeb0b1f2c; sha256 94148efe290a86178c6544714682fc3644cd6061d5596fadb594934156962f54},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.02476. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Wireless Capsule Endoscopy (WCE) captures and streams video while passing through a patient's Gastrointestinal (GI) tract and is used to examine its irregularities. Although advantageous over conventional endoscopy, WCE suffers from limitations related to capsule size and wireless transmission, resulting in images with coarser resolution. This work presents UnCapsTSR, an unsupervised transformer-based Generative Adversarial Network (GAN) framework for improving the spatial resolution of Low-Resolution (LR) WCE images. The proposed method accomplishes SR without explicit degradation estimation of real-world LR data and eliminates the need for true LR-HR pairs. UnCapsTSR employs a Bilateral Total Variation (BTV) loss to ensure spatial continuity in SR images. A newly curated dataset from the Kvasir Capsule dataset is also presented for training WCE SR models. Generalizability is validated on KID and GIANA datasets that are not used during training. A new non-reference metric, Endoscopy Quality Metric (EndoQM), is introduced for quantitative evaluation of domain-specific WCE data. Experiments demonstrate consistent improvement over state-of-the-art unsupervised SR approaches using NIQE, BRISQUE, PIQE, and EndoQM. Statistical evaluation shows 40 to 80 percent improvement in EndoQM from LR to SR across the evaluated datasets.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-03 in cs.CV).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2609.02476 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-17T05:25:58.125Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-03?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).