Metraipolis › archive › dc_5397265659fe

Evaluating Generalization and Long-Term Stability of Smartwatch-Based Cuffless Blood Pressure Monitoring — arXiv:2610.39394

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.39394
License (as archived)
CC0-1.0
Archived
2026-11-01T03:01:02.603Z
SHA-256 of the archived text
56a89f159b4cf25c5cc5df8af478ea0c9ce66235fd2d532cd37f03eae4c300a2
Stable URL of this page
https://metraipolis.com/documento/dc_5397265659fe

How to cite

Evaluating Generalization and Long-Term Stability of Smartwatch-Based Cuffless Blood Pressure Monitoring — arXiv:2610.39394 — arXiv (en), https://arxiv.org/abs/2610.39394 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_5397265659fe (Metraipolis archive dc_5397265659fe, sha256 56a89f159b4cf25c5cc5df8af478ea0c9ce66235fd2d532cd37f03eae4c300a2)
BibTeX
@misc{dc5397265659fe,
  title = {Evaluating Generalization and Long-Term Stability of Smartwatch-Based Cuffless Blood Pressure Monitoring — arXiv:2610.39394},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.39394},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_5397265659fe; sha256 56a89f159b4cf25c5cc5df8af478ea0c9ce66235fd2d532cd37f03eae4c300a2},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.39394. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Smartwatch-based cuffless blood pressure (BP) monitoring is a promising low-burden solution for long-term cardiovascular management, but practical deployment remains constrained by model complexity, uncertain cross-dataset generalization, and insufficient evidence on long-term tracking stability. This study presents an efficient Signal-Context Gated Fusion Network (SCGBPNet) for cuffless BP estimation from photoplethysmography (PPG) signals. SCGBPNet integrates signal-level representations through self-attention and further incorporates subject-specific contextual information via a compact gated fusion module. On Aurora-BP, SCGBPNet achieved SBP/DBP mean absolute errors (MAEs) of 7.08/4.90 mmHg, compared with 6.44/4.89 mmHg under within-dataset validation on the private smartwatch dataset, indicating a modest within-dataset discrepancy. Cross-dataset transfer from Aurora-BP to the smartwatch dataset increased the MAEs to 8.98/6.47 mmHg, demonstrating substantial cross-dataset degradation. For long-term stability, the proposed method showed low week-to-week performance variation and a low daily decay rate, indicating good stability over a follow-up period of more than one month. Nevertheless, estimation accuracy deteriorated when BP deviated substantially from an individual's baseline. These findings indicate that favorable aggregate MAE alone should not be interpreted as evidence of deployment-ready performance. More systematic and stratified evaluation across dataset settings, BP ranges, and baseline-deviation levels is needed to assess the practical reliability of smartwatch-based cuffless BP monitoring.

Tema degli esploratori: statistica e scienza dei dati (elenco arXiv eess.SP, nuovi lavori del giorno).
Categorie arXiv: Signal Processing (eess.SP).
Pagina del lavoro: https://arxiv.org/abs/2610.39394 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-01T02:25:45.620Z dalla pagina https://arxiv.org/list/eess.SP/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).