Metraipolis › archive › dc_5370e3cb7060

OmniRAS: Standardizing Foundation Model Training and Evaluation in Robot-Assisted Surgery — arXiv:2608.31048

Source
arXiv (en)
Original
https://arxiv.org/abs/2608.31048
License (as archived)
CC0-1.0
Archived
2026-10-17T10:43:06.329Z
SHA-256 of the archived text
9816eda262c8bec1a2906d0ce445649d89ad976e40c53c7683cb948f0deca64d
Stable URL of this page
https://metraipolis.com/documento/dc_5370e3cb7060

How to cite

OmniRAS: Standardizing Foundation Model Training and Evaluation in Robot-Assisted Surgery — arXiv:2608.31048 — arXiv (en), https://arxiv.org/abs/2608.31048 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_5370e3cb7060 (Metraipolis archive dc_5370e3cb7060, sha256 9816eda262c8bec1a2906d0ce445649d89ad976e40c53c7683cb948f0deca64d)
BibTeX
@misc{dc5370e3cb7060,
  title = {OmniRAS: Standardizing Foundation Model Training and Evaluation in Robot-Assisted Surgery — arXiv:2608.31048},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2608.31048},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_5370e3cb7060; sha256 9816eda262c8bec1a2906d0ce445649d89ad976e40c53c7683cb948f0deca64d},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.31048. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Few foundation models exist for robot-assisted surgery, partly because large robotic-surgery video corpora are difficult to assemble and existing models are evaluated mostly on laparoscopic benchmarks. Further, most existing models are evaluated on a small set of public benchmarks, mostly focused on laparoscopic surgery. We present OmniRAS, a family of 1B- and 2B-parameter V-JEPA-2.1 encoders for robot-assisted surgery, and detail their training. First, we release two densely annotated robotic-cholecystectomy datasets: OmniRAS-PR and a multi-label YT-Chole tool-verb-target task, the first triplet-style annotation for robotic cholecystectomy, together with splits, probe protocols, and an inter-rater study validating the shared phase ontology. Second, we document continued pretraining at up to 256 compute nodes with global batch 6,144 over 19 sources totaling approximately 2,650 hours of surgical video, 51% robotic, and analyze compute and data composition. Third, we evaluate against raw V-JEPA-2.1 and specialized surgical models on six tasks spanning triplet, phase, and step recognition, action segmentation, and detection, under frozen-encoder and final-four-block fine-tuning regimes. Across three seeds, this yields 254 downstream runs, including 109 with partial backbone fine-tuning. The best OmniRAS models achieve the strongest adapted results across all task families, while frozen differences are smaller.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-01 in eess.IV).
Categorie arXiv: Image and Video Processing (eess.IV).
Pagina del lavoro: https://arxiv.org/abs/2608.31048 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-17T10:33:05.796Z dalla pagina https://arxiv.org/catchup/eess.IV/2026-09-01?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).