Metraipolis › archive › dc_51b42386dc63
Laboratory characterization of Hierarchical Fringe Tracking — arXiv:2609.05205
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.05205
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-17T00:11:20.736Z
- SHA-256 of the archived text
ae23ab7b97329331562b5b323fb890fc0819436fea7b323289ac196be8b22e1f- Stable URL of this page
https://metraipolis.com/documento/dc_51b42386dc63
How to cite
Laboratory characterization of Hierarchical Fringe Tracking — arXiv:2609.05205 — arXiv (en), https://arxiv.org/abs/2609.05205 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_51b42386dc63 (Metraipolis archive dc_51b42386dc63, sha256 ae23ab7b97329331562b5b323fb890fc0819436fea7b323289ac196be8b22e1f)
BibTeX
@misc{dc51b42386dc63,
title = {Laboratory characterization of Hierarchical Fringe Tracking — arXiv:2609.05205},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.05205},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_51b42386dc63; sha256 ae23ab7b97329331562b5b323fb890fc0819436fea7b323289ac196be8b22e1f},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.05205. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
One of the main limitations in long-baseline interferometry lies in its fringe tracking sensitivity. The challenge is therefore to maximize this sensitivity while minimizing the spreading of the signal on the detector. This is the goal at the core of the hierarchical fringe tracking (HFT) concept. We present the laboratory characterization of the $2^{nd}$ generation HFT chips operating in the near infrared (H band) for up to 4 telescopes with more linear phase and group delay estimators, allowing a strong simplification of the tracking algorithm. We show a comparison between theoretical intensity outputs for an optimized phase delay chip, and the laboratory measurements of two chips with different designs. The results do not reach the expectations but get close to them with the 10-outputs chip. Ultimately, this new chip is intended for implementation on the VLTI, CHARA or on the future Xuyi 100m-baseline Stellar Interferometer using three telescopes.
Tema degli esploratori: fisica e astronomia (retro-catalogo arXiv: annunci del 2026-09-07 in astro-ph.IM).
Categorie arXiv: Instrumentation and Methods for Astrophysics (astro-ph.IM).
Pagina del lavoro: https://arxiv.org/abs/2609.05205 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-16T23:53:20.805Z dalla pagina https://arxiv.org/catchup/astro-ph.IM/2026-09-07?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).