Metraipolis › archive › dc_5034044ce416

Frequency-Frame Covariance for Reactive-Power Scalarization — arXiv:2611.05913

Source
arXiv (en)
Original
https://arxiv.org/abs/2611.05913
License (as archived)
CC0-1.0
Archived
2026-11-05T18:39:56.134Z
SHA-256 of the archived text
e4cd5d1401804f732cd60b10bac4d33b60e56f83593f271d96dbf28d51710981
Stable URL of this page
https://metraipolis.com/documento/dc_5034044ce416

How to cite

Frequency-Frame Covariance for Reactive-Power Scalarization — arXiv:2611.05913 — arXiv (en), https://arxiv.org/abs/2611.05913 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_5034044ce416 (Metraipolis archive dc_5034044ce416, sha256 e4cd5d1401804f732cd60b10bac4d33b60e56f83593f271d96dbf28d51710981)
BibTeX
@misc{dc5034044ce416,
  title = {Frequency-Frame Covariance for Reactive-Power Scalarization — arXiv:2611.05913},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2611.05913},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_5034044ce416; sha256 e4cd5d1401804f732cd60b10bac4d33b60e56f83593f271d96dbf28d51710981},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.05913. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Measured voltage and current waveforms may be represented in a reference frame whose frequency differs from the physical fundamental frequency. Reactive-power readouts calculated from such frequency-shifted coordinates may change if their readout operators are not transformed consistently. This paper presents a frequency-frame covariance formulation for finite-spectrum, zero-mean periodic waveforms with complete harmonic information over one physical period. A necessary and sufficient covariance condition is derived, requiring the readout operator to transform consistently with the waveform representation. Consequently, frequency-dependent harmonic weights must be evaluated at physical harmonic orders rather than relative frame labels. In particular, the derivative/Iliovici readout equals a relative-derivative contribution plus an explicit reference contribution. The formulation also separates readout-operator errors from errors caused by changes in the physical components retained by waveform projections. Three analytical cases illustrate conditional carrier recovery for a memoryless resistor, physical-frequency weighting at relative zero in an RLC branch, and the possibility that an exact reactive-power scalar can coexist with a substantial waveform error after projection. The scope is deterministic calculation consistency in frequency-shifted coordinates rather than instrument measurement uncertainty.

Tema degli esploratori: calcolo e infrastrutture (elenco arXiv eess.SY, nuovi lavori del giorno).
Categorie arXiv: Signal Processing (eess.SP) ; Systems and Control (eess.SY); Mathematical Physics (math-ph).
Pagina del lavoro: https://arxiv.org/abs/2611.05913 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-05T18:31:46.494Z dalla pagina https://arxiv.org/list/eess.SY/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).