Metraipolis › archive › dc_4fe328adb645
Anatomy-Aware Synthesis of Post-Contrast Breast MRI from Pre-Contrast Images — arXiv:2609.27015
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.27015
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-08T12:34:36.752Z
- SHA-256 of the archived text
e78330688a6fd8629bb3bcf721cc3800c624d0fe36544833b1f2a1dfbd2c4685- Stable URL of this page
https://metraipolis.com/documento/dc_4fe328adb645
How to cite
Anatomy-Aware Synthesis of Post-Contrast Breast MRI from Pre-Contrast Images — arXiv:2609.27015 — arXiv (en), https://arxiv.org/abs/2609.27015 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_4fe328adb645 (Metraipolis archive dc_4fe328adb645, sha256 e78330688a6fd8629bb3bcf721cc3800c624d0fe36544833b1f2a1dfbd2c4685)
BibTeX
@misc{dc4fe328adb645,
title = {Anatomy-Aware Synthesis of Post-Contrast Breast MRI from Pre-Contrast Images — arXiv:2609.27015},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.27015},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_4fe328adb645; sha256 e78330688a6fd8629bb3bcf721cc3800c624d0fe36544833b1f2a1dfbd2c4685},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.27015. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
We developed an anatomy-aware deep learning framework to synthesize post-contrast breast MRI from pre-contrast images, emphasizing tumor and background parenchymal enhancement (BPE) regions. This retrospective study included 649 patients with 6,251 paired pre-contrast and post-contrast images. The framework integrates breast mask consistency, lesion-region supervision, and BPE-region supervision into an image-to-image translation model. Evaluation included quantitative image quality metrics, a reader study with two breast radiologists, and downstream Ki-67 classification. The proposed method outperformed Pix2Pix, Pix2PixHD, diffusion-based synthesis, and mask-supervised baselines in whole-image and regional evaluations. Ki-67 classification showed no statistically significant performance differences across real- and synthetic-image training and testing settings, although this does not establish equivalence. These findings suggest that anatomy-aware supervision improves synthesis fidelity and support further investigation of synthetic post-contrast MRI for contrast-free imaging workflows. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-24 in cs.CV). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2609.27015 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-08T12:12:35.634Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-24?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).