Metraipolis › archive › dc_4f93af3366fe
Coordinated Dynamic Operation of Integrated Electrolyzer-Compressor Systems — arXiv:2608.11929
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.11929
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-19T06:06:25.770Z
- SHA-256 of the archived text
728b67642c39f7c5ba11ae1dbc1e316b5e77690977fc2333f680eb5c0b3e2f3e- Stable URL of this page
https://metraipolis.com/documento/dc_4f93af3366fe
How to cite
Coordinated Dynamic Operation of Integrated Electrolyzer-Compressor Systems — arXiv:2608.11929 — arXiv (en), https://arxiv.org/abs/2608.11929 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_4f93af3366fe (Metraipolis archive dc_4f93af3366fe, sha256 728b67642c39f7c5ba11ae1dbc1e316b5e77690977fc2333f680eb5c0b3e2f3e)
BibTeX
@misc{dc4f93af3366fe,
title = {Coordinated Dynamic Operation of Integrated Electrolyzer-Compressor Systems — arXiv:2608.11929},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.11929},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_4f93af3366fe; sha256 728b67642c39f7c5ba11ae1dbc1e316b5e77690977fc2333f680eb5c0b3e2f3e},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.11929. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
The increasing interaction between power and hydrogen sectors highlights the importance of coordinated operation of electrolyzers and electric-driven compressor stations (EDCSs). This becomes particularly of higher importance under transient disturbances. However, coordinated dynamic interactions of these coupled subsystems remain largely unexplored. This article addresses such gap by developing a dynamic model for an integrated electrolyzer-EDCS system and designing appropriate PID control schemes to address the potential disturbances affecting either component. To this end, linearized models of the electrolyzer and EDCS are first derived to enable systematic controller design. Then, two PID controllers, representing conservative and fast-tracking designs, are developed to coordinate the system response. The developed coordinated model is examined and verified under four different cases. The results demonstrate the effectiveness of the proposed model under disturbances from the compressor driver or the electrolyzer. Controlling the electrolyzer flow in response to EDCS disturbances coordinates system dynamics and mitigates undesirable transient fluctuations. Conversely, under electrolyzer disturbances, regulating the EDCS torque eliminates inconsistent responses in pressure, flow, and rotational speed, while preventing hazardous transient undershoots and overshoots. Overall, the proposed framework guarantees transient stability and operational reliability of the integrated electrolyzer-EDCS system. Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-08-13 in eess.SY). Categorie arXiv: Systems and Control (eess.SY). Pagina del lavoro: https://arxiv.org/abs/2608.11929 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-19T05:56:09.568Z dalla pagina https://arxiv.org/catchup/eess.SY/2026-08-13?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).