Metraipolis › archive › dc_4df47fdaa3ea

Sliding-scale Insulin Does Not Control Steroid-induced Hyperglycemia in a Non-diabetic Patient, No Matter How You Tune It — arXiv:2610.08730

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.08730
License (as archived)
CC0-1.0
Archived
2026-10-07T21:07:22.923Z
SHA-256 of the archived text
5d2c116fc6cafaa1e3874ef3d24c225a3d6c62a230110d10f4a4b1c2f0c2dc30
Stable URL of this page
https://metraipolis.com/documento/dc_4df47fdaa3ea

How to cite

Sliding-scale Insulin Does Not Control Steroid-induced Hyperglycemia in a Non-diabetic Patient, No Matter How You Tune It — arXiv:2610.08730 — arXiv (en), https://arxiv.org/abs/2610.08730 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_4df47fdaa3ea (Metraipolis archive dc_4df47fdaa3ea, sha256 5d2c116fc6cafaa1e3874ef3d24c225a3d6c62a230110d10f4a4b1c2f0c2dc30)
BibTeX
@misc{dc4df47fdaa3ea,
  title = {Sliding-scale Insulin Does Not Control Steroid-induced Hyperglycemia in a Non-diabetic Patient, No Matter How You Tune It — arXiv:2610.08730},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.08730},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_4df47fdaa3ea; sha256 5d2c116fc6cafaa1e3874ef3d24c225a3d6c62a230110d10f4a4b1c2f0c2dc30},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.08730. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Sliding-scale correction insulin is the standard hospital response to high blood glucose. Its constants were derived in people who secrete no insulin, yet it is routinely ordered for patients whose own secretion is intact. We represent the correction rule as a proportional controller with a deadband, sampled four-hourly, acting on a glucose model built from published physiology, including pancreatic feedback. We derive the sensitivity of glucose to exogenous insulin, evaluate it in 4,995 virtual patients spanning published parameter ranges, and calibrate the model to a non-diabetic adolescent receiving high-dose corticosteroids and parenteral nutrition, with 45 bedside glucose measurements. Here we show that endogenous regulation restores glucose with a time constant of 11.5 minutes, against 64 minutes for injected insulin to peak, so most of each dose replaces the patient's own secretion and the ordered rule moves mean glucose by less than 1.5 mg/dL. The ordered correction factor exceeds per-unit potency in every virtual patient. Because potency falls as glucose rises, in 99.5% of virtual patients no constant correction factor is both effective at 190 mg/dL and free of overshoot at 110 mg/dL; the mismatch exceeds 25% in 79% and grows with the glucose of half-maximal secretion. Four-hour sampling is phase-locked to dextrose in medication diluents and misses the resulting excursions. When endogenous secretion is intact, the sliding scale fails for structural reasons that retuning cannot fix. A continuous insulin infusion co-delivered with the dextrose and adjusted once daily on mean glucose matches what four-hour monitoring can measure.

Tema degli esploratori: calcolo e infrastrutture (elenco arXiv eess.SY, nuovi lavori del giorno).
Categorie arXiv: Systems and Control (eess.SY) ; Signal Processing (eess.SP); Tissues and Organs (q-bio.TO).
Pagina del lavoro: https://arxiv.org/abs/2610.08730 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-07T20:38:49.157Z dalla pagina https://arxiv.org/list/eess.SY/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).