Metraipolis › archive › dc_4dc2516d2a0b
ViTexSZ: Heterogeneous Vision-Text Knowledge Distillation for EEG Seizure Detection — arXiv:2608.21445
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.21445
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-18T08:56:33.720Z
- SHA-256 of the archived text
1dac838fb933048ee4360737d9a0905423e4255d267bf65aacc5ca429319ee9e- Stable URL of this page
https://metraipolis.com/documento/dc_4dc2516d2a0b
How to cite
ViTexSZ: Heterogeneous Vision-Text Knowledge Distillation for EEG Seizure Detection — arXiv:2608.21445 — arXiv (en), https://arxiv.org/abs/2608.21445 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_4dc2516d2a0b (Metraipolis archive dc_4dc2516d2a0b, sha256 1dac838fb933048ee4360737d9a0905423e4255d267bf65aacc5ca429319ee9e)
BibTeX
@misc{dc4dc2516d2a0b,
title = {ViTexSZ: Heterogeneous Vision-Text Knowledge Distillation for EEG Seizure Detection — arXiv:2608.21445},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.21445},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_4dc2516d2a0b; sha256 1dac838fb933048ee4360737d9a0905423e4255d267bf65aacc5ca429319ee9e},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.21445. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Automated seizure detection from electroencephalography (EEG) is essential for continuous neurological monitoring, particularly for subclinical epileptic seizures that may exhibit only subtle electrographic changes. Existing time-series methods are often designed for fixed EEG channel configurations, thereby limiting their applicability to heterogeneous EEG recordings with irregular channel layouts. Although visual and language modeling offer promising alternatives, aligning heterogeneous EEG representations with clinical semantics remains challenging. We introduce ViTexSZ, a heterogeneous Vision-Text knowledge distillation framework for EEG seizure detection. ViTexSZ converts EEG recordings into structured waveform images and introduces a query-based multi-channel alignment module that maps source-dependent visual features into a unified token space. A heterogeneous teacher further integrates the aligned EEG representations with clinical prompts through a multimodal large language model, associating high-level clinical semantics with seizure-related evidence. Vision-text knowledge distillation then transfers the teacher representations to a lightweight student during detection. Experiments on four EEG seizure datasets demonstrate the generalizability of ViTexSZ across both subclinical and general seizure detection scenarios, achieving the highest accuracy on all datasets and relative improvements of up to 12.9% over the second-best baselines, showing its effectiveness. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-08-25 in cs.CV). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2608.21445 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-18T08:48:09.084Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-08-25?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).