Metraipolis › archive › dc_4d3f92372ee3
The MS Unidirectional Current as a Generalization of the ABC Absorption Current — arXiv:2608.29969
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.29969
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-17T10:14:49.339Z
- SHA-256 of the archived text
11044ab4f6ea853a54e0ab766ff6f8da44a7a0886f0ec083ea45a3e3e3a98bb1- Stable URL of this page
https://metraipolis.com/documento/dc_4d3f92372ee3
How to cite
The MS Unidirectional Current as a Generalization of the ABC Absorption Current — arXiv:2608.29969 — arXiv (en), https://arxiv.org/abs/2608.29969 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_4d3f92372ee3 (Metraipolis archive dc_4d3f92372ee3, sha256 11044ab4f6ea853a54e0ab766ff6f8da44a7a0886f0ec083ea45a3e3e3a98bb1)
BibTeX
@misc{dc4d3f92372ee3,
title = {The MS Unidirectional Current as a Generalization of the ABC Absorption Current — arXiv:2608.29969},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.29969},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_4d3f92372ee3; sha256 11044ab4f6ea853a54e0ab766ff6f8da44a7a0886f0ec083ea45a3e3e3a98bb1},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.29969. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
For a free scalar particle in one spatial dimension, in a single-pass half-line geometry, we compare the absorbing Robin boundary condition with the generalized Marchewka--Schuss (MS) unidirectional-current family. Robin absorption is characterized by a single parameter $\kappa>0$: once $\kappa$ is specified, its momentum-dependent absorption profile is fixed. In the generalized MS construction, by contrast, the detector response is described by a spectral function $\lambda(k)$, subject to the positivity and subnormalization conditions of the detection law. We show that every Robin choice of $\kappa$ corresponds to the particular MS calibration $\lambda_\kappa(k)=\pi\kappa/(k+\kappa)^2$, which reproduces the complete Robin absorption current for every admissible one-sided spectral amplitude and at every time. Thus the entire one-parameter Robin absorption family is contained within the generalized MS family. The MS construction is more general: the choice $\lambda_{\rm full}(k)=\pi/(4k)$ gives unit absorption efficiency for every wave number, which cannot be achieved by any fixed Robin parameter. In this precise sense, the generalized MS detector process extends the Robin absorbing-boundary family. We also compare their asymptotic behavior in the ballistic fixed-ray regime and in the fixed-distance late-time limit.
Tema degli esploratori: fisica e astronomia (retro-catalogo arXiv: annunci del 2026-09-01 in quant-ph).
Categorie arXiv: Quantum Physics (quant-ph).
Pagina del lavoro: https://arxiv.org/abs/2608.29969 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-17T10:03:37.601Z dalla pagina https://arxiv.org/catchup/quant-ph/2026-09-01?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).