Metraipolis › archive › dc_4d3905640956

High-Resolution Quantitative MRI Using Contrast-Domain Multiscale Energy (MuSE) Regularization — arXiv:2611.05132

Source
arXiv (en)
Original
https://arxiv.org/abs/2611.05132
License (as archived)
CC0-1.0
Archived
2026-11-04T19:14:23.290Z
SHA-256 of the archived text
9fde6eccc6a6c0d852c864bc5b3366b83295d1ee97d5c9255530c5095f3e922f
Stable URL of this page
https://metraipolis.com/documento/dc_4d3905640956

How to cite

High-Resolution Quantitative MRI Using Contrast-Domain Multiscale Energy (MuSE) Regularization — arXiv:2611.05132 — arXiv (en), https://arxiv.org/abs/2611.05132 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_4d3905640956 (Metraipolis archive dc_4d3905640956, sha256 9fde6eccc6a6c0d852c864bc5b3366b83295d1ee97d5c9255530c5095f3e922f)
BibTeX
@misc{dc4d3905640956,
  title = {High-Resolution Quantitative MRI Using Contrast-Domain Multiscale Energy (MuSE) Regularization — arXiv:2611.05132},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2611.05132},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_4d3905640956; sha256 9fde6eccc6a6c0d852c864bc5b3366b83295d1ee97d5c9255530c5095f3e922f},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.05132. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Quantitative MRI methods can offer tissue parameter maps (e.g. T1) that are comparable across scanners, sessions and subjects, together with multiple contrast-weighted images from a single scan. However, most data are acquired at 1 mm, which limits their use in neurodegenerative diseases that affect fine brain structures. We introduce, to our knowledge, the first diffusion-model-based reconstruction for quantitative MRI at 0.5 mm isotropic resolution from scans of less than 5 minutes, which has eightfold smaller voxel volume than clinical protocols. The key idea is to apply the prior to the synthesized contrast images rather than to the subspace coefficients. The prior is then independent of the temporal basis and the sequence, which improves generalization and allows a 2-D multiscale energy (MuSE) model trained on grayscale CelebA face images to be used without any MRI training data. The explicit energy makes reconstruction MAP estimation by a step-size-free majorize-minimize algorithm that regularizes a rotating subset of contrasts along different axes, which makes 3-D multi-contrast reconstruction tractable. For 3-D radial MPnRAGE at 7 T in 4.3 min, MuSE reduced the phantom NRMSE from 0.133 (CG-SENSE) and 0.091 (L1-wavelet) to 0.074 and the WM T1 interquartile range from 117 and 47 ms to 38 ms, and it was demonstrated in vivo at 7 T.

Tema degli esploratori: statistica e scienza dei dati (elenco arXiv eess.IV, nuovi lavori del giorno).
Categorie arXiv: Image and Video Processing (eess.IV).
Pagina del lavoro: https://arxiv.org/abs/2611.05132 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-04T18:49:07.635Z dalla pagina https://arxiv.org/list/eess.IV/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).