Metraipolis › archive › dc_4d281e574c7b
Calibration electronics for the 30 and 40 GHz instrument (TFGI) of the QUIJOTE experiment — arXiv:2609.21127
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.21127
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-10T03:04:37.294Z
- SHA-256 of the archived text
56f0015ebf83f67be3a8a646b34eb3ce96ff4517e4bdfc93530c1887f6efdb8e- Stable URL of this page
https://metraipolis.com/documento/dc_4d281e574c7b
How to cite
Calibration electronics for the 30 and 40 GHz instrument (TFGI) of the QUIJOTE experiment — arXiv:2609.21127 — arXiv (en), https://arxiv.org/abs/2609.21127 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_4d281e574c7b (Metraipolis archive dc_4d281e574c7b, sha256 56f0015ebf83f67be3a8a646b34eb3ce96ff4517e4bdfc93530c1887f6efdb8e)
BibTeX
@misc{dc4d281e574c7b,
title = {Calibration electronics for the 30 and 40 GHz instrument (TFGI) of the QUIJOTE experiment — arXiv:2609.21127},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.21127},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_4d281e574c7b; sha256 56f0015ebf83f67be3a8a646b34eb3ce96ff4517e4bdfc93530c1887f6efdb8e},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.21127. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
The 30 and 40 GHz instruments of the QUIJOTE radio astronomy experiment use very sensitive receivers which need to be characterized both to ensure their proper functioning and for their calibration. Given the age of the PXI-1031DC device used up until now for this purpose, the design of a new device, the Calibrator TFGI QUIJOTE, has been proposed. This new device has been designed with the idea of being simple and modular, easy to use and upgrade. It is built on a Raspberry Pi 5 system, using an MCC 118 as analog reading module. This system, widely known among both makers and professionals, not only meets the requirements of modularity and ease of use, but also ensures that the device is much more economically competitive than the PXI. A first version of the device has been built and tested, obtaining good results in accuracy and ease of use. Tema degli esploratori: fisica e astronomia (retro-catalogo arXiv: annunci del 2026-09-21 in astro-ph.IM). Categorie arXiv: Instrumentation and Methods for Astrophysics (astro-ph.IM) ; Systems and Control (eess.SY); Instrumentation and Detectors (physics.ins-det). Pagina del lavoro: https://arxiv.org/abs/2609.21127 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-10T02:42:39.364Z dalla pagina https://arxiv.org/catchup/astro-ph.IM/2026-09-21?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).