Metraipolis › archive › dc_4d011adc0653

Evaluating Counterfactual Sensitivity to Patient Information in Medication-Safety Reasoning — arXiv:2608.03028

Source
arXiv (en)
Original
https://arxiv.org/abs/2608.03028
License (as archived)
CC0-1.0
Archived
2026-10-31T12:15:32.023Z
SHA-256 of the archived text
965ebe650bd74386cffe4692bceb82b9cd7ed8d4cd5549a259bb7ad1ad1b82a3
Stable URL of this page
https://metraipolis.com/documento/dc_4d011adc0653

How to cite

Evaluating Counterfactual Sensitivity to Patient Information in Medication-Safety Reasoning — arXiv:2608.03028 — arXiv (en), https://arxiv.org/abs/2608.03028 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_4d011adc0653 (Metraipolis archive dc_4d011adc0653, sha256 965ebe650bd74386cffe4692bceb82b9cd7ed8d4cd5549a259bb7ad1ad1b82a3)
BibTeX
@misc{dc4d011adc0653,
  title = {Evaluating Counterfactual Sensitivity to Patient Information in Medication-Safety Reasoning — arXiv:2608.03028},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2608.03028},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_4d011adc0653; sha256 965ebe650bd74386cffe4692bceb82b9cd7ed8d4cd5549a259bb7ad1ad1b82a3},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.03028. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Applying a valid medication-safety rule when its patient-specific conditions are not met can produce an incorrect decision. Existing medical evaluations largely use isolated and fixed scenarios. A model may therefore answer correctly by recalling a drug-risk association without showing that it used patient information to decide whether the rule applies. To address this gap, we introduce MedPIC-Bench, a benchmark of source-verifiable recommendations and expert-validated questions for patient-specific medication-safety reasoning. It combines guideline-following questions with paired counterfactual questions in which a controlled change in patient information changes whether a rule applies. The benchmark contains 467 questions annotated along six clinical and reasoning dimensions. Across 28 medical-specific, general, and proprietary LLMs, every model performs worse on counterfactual questions, with mean accuracy falling from 63.6\% to 45.1\%. Models perform well when an explicit patient attribute directly signals a familiar contraindication, but struggle when patient information must narrow or withdraw a safety warning. Model rationales often acknowledge the changed patient information, yet the final answers retain the previous safety judgment. This vulnerability persists among medical-specific LLMs, whose average CF performance trails that of general LLMs. MedPIC-Bench therefore makes conditional rule application measurable and highlights the limitations of static medication-safety accuracy for assessing patient-specific reliability.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-08-05 in cs.AI).
Categorie arXiv: Artificial Intelligence (cs.AI).
Pagina del lavoro: https://arxiv.org/abs/2608.03028 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-31T12:05:52.745Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-08-05?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).