Metraipolis › archive › dc_4ce60f6b7fde

Pulseflow: PPG Counterfactual Generation Via Latent Transport — arXiv:2609.33501

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.33501
License (as archived)
CC0-1.0
Archived
2026-10-07T22:37:31.133Z
SHA-256 of the archived text
b06212c125c8db88a12808b5c6cd0fae185b87823a4e4949f5d46a17037c89e5
Stable URL of this page
https://metraipolis.com/documento/dc_4ce60f6b7fde

How to cite

Pulseflow: PPG Counterfactual Generation Via Latent Transport — arXiv:2609.33501 — arXiv (en), https://arxiv.org/abs/2609.33501 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_4ce60f6b7fde (Metraipolis archive dc_4ce60f6b7fde, sha256 b06212c125c8db88a12808b5c6cd0fae185b87823a4e4949f5d46a17037c89e5)
BibTeX
@misc{dc4ce60f6b7fde,
  title = {Pulseflow: PPG Counterfactual Generation Via Latent Transport — arXiv:2609.33501},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.33501},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_4ce60f6b7fde; sha256 b06212c125c8db88a12808b5c6cd0fae185b87823a4e4949f5d46a17037c89e5},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.33501. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Photoplethysmography (PPG) has become an important modality for continuous cardiovascular monitoring, including atrial fibrillation (AF) detection. However, labeled AF recordings remain limited in many clinical settings, making model adaptation difficult when only limited target data are available. Generative modeling offers a natural way to alleviate this scarcity by synthesizing additional AF signals. Existing approaches, however, mainly generate samples that match the target condition without explicitly modeling how an observed source recording should be transformed, making it difficult to leverage abundant source recordings from a specific population or cohort for targeted augmentation. We introduce PulseFlow, a source-conditioned counterfactual generation framework that combines conditional representation learning with invertible latent transport to edit cardiac rhythm while retaining information from the source. Experiments across two clinical cohorts demonstrate effective rhythm transformation, measurable source correspondence, and improved AF classification under limited labels.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-29 in cs.LG).
Categorie arXiv: Machine Learning (cs.LG).
Pagina del lavoro: https://arxiv.org/abs/2609.33501 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-07T22:14:27.968Z dalla pagina https://arxiv.org/catchup/cs.LG/2026-09-29?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).