Metraipolis › archive › dc_4c313b13fa15
Interactive 3D Cutaway Visualization for Subsurface Target Localization in Robot-Assisted Surgery — arXiv:2611.02537
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2611.02537
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-03T18:57:16.512Z
- SHA-256 of the archived text
ef91d9b520baaae2422126d7c47a647830133f8490cd4b94536c76e996c8445c- Stable URL of this page
https://metraipolis.com/documento/dc_4c313b13fa15
How to cite
Interactive 3D Cutaway Visualization for Subsurface Target Localization in Robot-Assisted Surgery — arXiv:2611.02537 — arXiv (en), https://arxiv.org/abs/2611.02537 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_4c313b13fa15 (Metraipolis archive dc_4c313b13fa15, sha256 ef91d9b520baaae2422126d7c47a647830133f8490cd4b94536c76e996c8445c)
BibTeX
@misc{dc4c313b13fa15,
title = {Interactive 3D Cutaway Visualization for Subsurface Target Localization in Robot-Assisted Surgery — arXiv:2611.02537},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2611.02537},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_4c313b13fa15; sha256 ef91d9b520baaae2422126d7c47a647830133f8490cd4b94536c76e996c8445c},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.02537. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Purpose: Blended augmented reality (AR) overlays can provide ambiguous depth cues in which subsurface anatomy floats above the tissue surface. We investigate whether an interactive 3D cutaway visualization can improve robot-assisted target localization. Methods: We propose Virtual Box, an interactive 3D cutaway interface that allows users to independently manipulate the viewing perspective to inspect subsurface targets. In a controlled, counterbalanced within-subject tissue phantom study, 15 engineering students used Virtual Box and a depth-enhanced blended AR overlay to position a da Vinci instrument at virtual targets in a water tank. We used registered 3D transrectal ultrasound to measure 3D localization error and depth error. We also collected completion time and subjective ratings. Results: Virtual Box reduced mean 3D error from 12.92 to 4.96 mm (61.6% reduction) and depth error from 9.48 to 2.07 mm (78.2% reduction; both p < 0.001). Spatial understanding, depth perception, and confidence ratings were higher (all unadjusted p < 0.001), but completion time increased from 21.64 to 32.58 s (p = 0.008). Overall workload did not differ significantly. Conclusion: Virtual Box improved localization accuracy and perceived spatial understanding in this controlled task, with additional completion time, supporting further evaluation for surgical navigation. Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.RO, nuovi lavori del giorno). Categorie arXiv: Robotics (cs.RO). Pagina del lavoro: https://arxiv.org/abs/2611.02537 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-11-03T18:17:07.748Z dalla pagina https://arxiv.org/list/cs.RO/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).