Metraipolis › archive › dc_4b58ef3006bf

Data center tiers — Wikipedia (en)

Source
Wikipedia (en)
Original
https://en.wikipedia.org/wiki/Data_center_tiers
License (as archived)
CC-BY-SA-4.0
Archived
2026-10-05T22:57:39.839Z
SHA-256 of the archived text
d9bde56790b7db18c71a612566ab5c822250dcd2cec7498b2b2c6cce4f819af7
Stable URL of this page
https://metraipolis.com/documento/dc_4b58ef3006bf

How to cite

Data center tiers — Wikipedia (en) — Wikipedia (en), https://en.wikipedia.org/wiki/Data_center_tiers (CC-BY-SA-4.0); archived copy: https://metraipolis.com/documento/dc_4b58ef3006bf (Metraipolis archive dc_4b58ef3006bf, sha256 d9bde56790b7db18c71a612566ab5c822250dcd2cec7498b2b2c6cce4f819af7)
BibTeX
@misc{dc4b58ef3006bf,
  title = {Data center tiers — Wikipedia (en)},
  howpublished = {Wikipedia (en)},
  url = {https://en.wikipedia.org/wiki/Data_center_tiers},
  note = {License CC-BY-SA-4.0; archived copy https://metraipolis.com/documento/dc_4b58ef3006bf; sha256 d9bde56790b7db18c71a612566ab5c822250dcd2cec7498b2b2c6cce4f819af7},
  year = {2026}
}

Archived text

Reproduced under CC-BY-SA-4.0. Attribution: Wikipedia (en), https://en.wikipedia.org/wiki/Data_center_tiers. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Data center tiers are defined levels of resiliency and redundancy for IT facility infrastructure. They are widely used in the data center, ISP and cloud computing industries as a framework for designing and classifying high availability systems. The tier classification system was created by the Uptime Institute. The four tiers define increasing levels of redundancy in power supply, cooling and other critical infrastructure components. Higher tiers require that the facility remain operational — at the level of the tier below — even during maintenance or single component failures. Tier I: no redundancy. A single path for power and cooling, no redundant components. Tier II: partial N+1 redundancy for power and cooling components, but still a single distribution path. Tier III: full N+1 redundancy of all systems, including power supply and cooling distribution paths. Maintenance can be performed without taking the facility offline. Tier IV: 2N+1 redundancy of all systems. The facility can sustain any single failure without impacting the load. All cooling and power distribution paths are fully redundant and independently active. Most commercial data centers are certified to Tier III. Rather than building Tier IV facilities, many large cloud service providers instead use multiple availability zones to distribute their services geographically, achieving resilience across multiple physical sites.

Tema degli esploratori: calcolo e infrastrutture (deposito sistematico; ricerca «data center»).
Fonte: Wikipedia in inglese, voce «Data center tiers» — https://en.wikipedia.org/wiki/Data_center_tiers
Wikidata Q10343503 (dati Wikidata in CC0 1.0) — https://www.wikidata.org/wiki/Q10343503
Autori: i contributori di Wikipedia (cronologia: https://en.wikipedia.org/wiki/Data_center_tiers?action=history).
Licenza: Creative Commons Attribuzione-Condividi allo stesso modo 4.0 (CC BY-SA 4.0) — https://creativecommons.org/licenses/by-sa/4.0/. Il riuso richiede attribuzione e stessa licenza.
Estratto dell'introduzione non modificato nel contenuto; revisione 1356373627, consultata il 2026-10-05T22:47:49.957Z tramite l'API ufficiale di Wikipedia. Impronta SHA-256 dell'estratto: 7193405d57ce7644fad281d81f7fbca43b1f89342606c9b41531b19337d95839