Metraipolis › archive › dc_4b01ec106e99
Enhanced Real-Time 6-DOF Extended Reality Catheter Tracking for Evaluating Potential Improvement in Efficiency, Precision, and Depth Perception for Cardiac Interventions — arXiv:2608.07606
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.07606
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-19T09:12:24.087Z
- SHA-256 of the archived text
fd434c4821748ddaf6463eeb8812feae61aad2d4d7bb2b3de7a09281a4bba171- Stable URL of this page
https://metraipolis.com/documento/dc_4b01ec106e99
How to cite
Enhanced Real-Time 6-DOF Extended Reality Catheter Tracking for Evaluating Potential Improvement in Efficiency, Precision, and Depth Perception for Cardiac Interventions — arXiv:2608.07606 — arXiv (en), https://arxiv.org/abs/2608.07606 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_4b01ec106e99 (Metraipolis archive dc_4b01ec106e99, sha256 fd434c4821748ddaf6463eeb8812feae61aad2d4d7bb2b3de7a09281a4bba171)
BibTeX
@misc{dc4b01ec106e99,
title = {Enhanced Real-Time 6-DOF Extended Reality Catheter Tracking for Evaluating Potential Improvement in Efficiency, Precision, and Depth Perception for Cardiac Interventions — arXiv:2608.07606},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.07606},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_4b01ec106e99; sha256 fd434c4821748ddaf6463eeb8812feae61aad2d4d7bb2b3de7a09281a4bba171},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.07606. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Despite advances in 3D ultrasound, most percutaneous cardiac interventions still rely on 2D visualization, limiting depth perception and spatial understanding. To address this challenge, we developed an Extended Reality (XR)-based platform that enables real-time six-degree-of-freedom (6-DOF) catheter tracking and visualization within a patient-specific 3D heart model. The system combines a custom machine-vision algorithm for 5-DOF catheter tracking with a 3D-printed electromechanical encoder that measures catheter roll, providing complete 6-DOF motion reconstruction. In a proof-of-concept study, 20 novice medical students navigated an intracardiac echocardiography (ICE) catheter to six anatomical targets using either immersive 3D visualization or a conventional 2D cathlab-style view. Participants in the 3D condition completed the task in 54.6 seconds and traveled 1,939 mm on average, compared with 267.5 seconds and 7,854 mm in the 2D condition. Therefore, the XR-based 3D system was more than 5x faster and required ~5x less catheter travel. The 3D mode also improved targeting precision and reduced performance variability. Participants consistently rated immersive visualization higher for accuracy, speed, usability, and clinical value. Kinematic analysis showed smoother depth-axis navigation in 3D, whereas 2D users relied on repeated corrective movements. These findings demonstrate that XR-based visualization can substantially improve procedural training efficiency, precision, and motor control. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-08-11 in cs.RO). Categorie arXiv: Robotics (cs.RO) ; Artificial Intelligence (cs.AI); Human-Computer Interaction (cs.HC); Image and Video Processing (eess.IV). Pagina del lavoro: https://arxiv.org/abs/2608.07606 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-19T09:11:58.722Z dalla pagina https://arxiv.org/catchup/cs.RO/2026-08-11?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).