Finite-sample Calibration Guarantees for Binary Segmentation — arXiv:2611.09120

Source
arXiv (en)
Original
https://arxiv.org/abs/2611.09120
License (as archived)
CC0-1.0
Archived
2026-11-09T22:41:55.598Z
SHA-256 of the archived text
ba97669173a16ede73d52d5b6c4c70fa633c6a16af99db0e8108b63c40b59401
Stable URL of this page
https://metraipolis.com/documento/dc_4adc9a237dcf

How to cite

Finite-sample Calibration Guarantees for Binary Segmentation — arXiv:2611.09120 — arXiv (en), https://arxiv.org/abs/2611.09120 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_4adc9a237dcf (Metraipolis archive dc_4adc9a237dcf, sha256 ba97669173a16ede73d52d5b6c4c70fa633c6a16af99db0e8108b63c40b59401)
BibTeX
@misc{dc4adc9a237dcf,
  title = {Finite-sample Calibration Guarantees for Binary Segmentation — arXiv:2611.09120},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2611.09120},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_4adc9a237dcf; sha256 ba97669173a16ede73d52d5b6c4c70fa633c6a16af99db0e8108b63c40b59401},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.09120. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Machine learning based segmentation models are frequently miscalibrated, producing for each pixel a label prediction whose associated confidence does not accurately reflect the true underlying probability. This limitation is particularly critical in high-stakes applications such as medical image segmentation. Although several calibration methods have been proposed, only a small subset of them provides theoretical guarantees on the calibration error, i.e., they do not typically ensure that, with high probability, the model exhibits a low calibration error. In this work, we develop a post-hoc calibration method for which formal calibration guarantees can be established. To achieve this, we derive from standard concentration inequalities an improved theoretical bound that explicitly accounts for the spatial dependence inherent in binary segmentation outputs. We empirically demonstrate that the proposed calibrator satisfies the derived guarantee and outperforms existing post-hoc calibration approaches.

Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.LG, nuovi lavori del giorno).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV) ; Machine Learning (cs.LG).
Pagina del lavoro: https://arxiv.org/abs/2611.09120 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-09T22:33:47.175Z dalla pagina https://arxiv.org/list/cs.LG/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).