Metraipolis › archive › dc_4a152c244c3a
Deep learning for non-transvenous ICD screening: tailored neural network architectures, extended experiments, and explainability — arXiv:2610.37993
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2610.37993
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-01T02:23:20.724Z
- SHA-256 of the archived text
65987502ee5d011c2f9b422176807fc85f085af5b9bc49db190510463b81a97d- Stable URL of this page
https://metraipolis.com/documento/dc_4a152c244c3a
How to cite
Deep learning for non-transvenous ICD screening: tailored neural network architectures, extended experiments, and explainability — arXiv:2610.37993 — arXiv (en), https://arxiv.org/abs/2610.37993 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_4a152c244c3a (Metraipolis archive dc_4a152c244c3a, sha256 65987502ee5d011c2f9b422176807fc85f085af5b9bc49db190510463b81a97d)
BibTeX
@misc{dc4a152c244c3a,
title = {Deep learning for non-transvenous ICD screening: tailored neural network architectures, extended experiments, and explainability — arXiv:2610.37993},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2610.37993},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_4a152c244c3a; sha256 65987502ee5d011c2f9b422176807fc85f085af5b9bc49db190510463b81a97d},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.37993. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
This paper studies two non-transvenous implantable cardioverter-defibrillators (ICDs), namely the Subcutaneous ICD (S-ICD) and the Extravascular ICD (EV-ICD). Both avoid the complications of transvenous leads but are prone to oversensing, which can trigger inappropriate shocks associated with increased mortality. Oversensing risk is predicted by the ratio of T- or P-wave amplitude to R-wave amplitude (T:R, P:R), and these ratios vary over a 24-hour period. Yet S-ICD screening uses a single 10-second electrocardiogram (ECG) segment, and the EV-ICD has no formal screening protocol whatsoever. We present a 24-hour ambulatory screening framework for both devices which includes the first T:R analysis in an EV-ICD cohort and the first full evaluation of P:R prediction. We introduce AmpRatioNet, a family of 1D convolutional neural network architectures operating directly on the ECG signal, and benchmark it against the best existing approach - based on 2D phase space reconstruction images. Evaluation uses 4,605 clinician-annotated 10-second segments from 89 patients, with patient-level 10-fold cross-validation and bootstrap confidence intervals. AmpRatioNet-SE demonstrates superior performance on every metric in each setting with no device- or ratio-specific redesign. An explainability analysis against interpretable classical peak labelling algorithms shows that AmpRatioNet-SE's increase in error on oversensing-prone segments is up to 14 times smaller than theirs. Segment-level predictions are aggregated into a 24-hour timeline, extending S-ICD screening beyond 10 seconds and offering a plausible EV-ICD screening pathway pending device-level validation. Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.LG, nuovi lavori del giorno). Categorie arXiv: Machine Learning (cs.LG). Pagina del lavoro: https://arxiv.org/abs/2610.37993 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-11-01T02:12:44.094Z dalla pagina https://arxiv.org/list/cs.LG/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).