Metraipolis › archive › dc_49f69f9be0f4

SurgGaze: Implicit Calibration for Accurate Gaze Analysis in Operating Rooms with Wearable Eyetrackers — arXiv:2609.25612

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.25612
License (as archived)
CC0-1.0
Archived
2026-10-08T15:06:54.617Z
SHA-256 of the archived text
ce6afb8d8901a94b1f5684cfe2636272ab7ae7f4cb2734818137aaa4b2505edb
Stable URL of this page
https://metraipolis.com/documento/dc_49f69f9be0f4

How to cite

SurgGaze: Implicit Calibration for Accurate Gaze Analysis in Operating Rooms with Wearable Eyetrackers — arXiv:2609.25612 — arXiv (en), https://arxiv.org/abs/2609.25612 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_49f69f9be0f4 (Metraipolis archive dc_49f69f9be0f4, sha256 ce6afb8d8901a94b1f5684cfe2636272ab7ae7f4cb2734818137aaa4b2505edb)
BibTeX
@misc{dc49f69f9be0f4,
  title = {SurgGaze: Implicit Calibration for Accurate Gaze Analysis in Operating Rooms with Wearable Eyetrackers — arXiv:2609.25612},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.25612},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_49f69f9be0f4; sha256 ce6afb8d8901a94b1f5684cfe2636272ab7ae7f4cb2734818137aaa4b2505edb},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.25612. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Accurate gaze tracking is essential for understanding surgeons' visual attention and cognitive processes during laparoscopic surgery, yet wearable eye trackers produce large errors systematically correlated with ground-truth gaze locations, as demonstrated in Study 1. We introduce SurgGaze, an implicit calibration method that corrects these errors using high-confidence surgical moments. Building on evidence that surgeons' gaze converges near the tool-tissue contact point (TTCP) during dissection, SurgGaze uses TTCP as a surrogate for true gaze to construct training pairs. We evaluate SurgGaze in a simulated operating room trial and an authentic operating room case study. In simulation, SurgGaze reduced gaze estimation error by 40.6%, significantly outperforming conventional 9-point explicit calibration. The case study showed that these moments provide reliable training data and that calibrated gaze improves interpretation of surgeons' attention beyond numeric error reduction. These findings demonstrate that structured behavioral signals can enable implicit calibration for gaze tracking in complex real-world settings.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-23 in cs.HC).
Categorie arXiv: Human-Computer Interaction (cs.HC).
Pagina del lavoro: https://arxiv.org/abs/2609.25612 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-08T14:34:31.468Z dalla pagina https://arxiv.org/catchup/cs.HC/2026-09-23?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).