Metraipolis › archive › dc_48c28ad99588
Hyperon-antihyperon system in electron-positron annihilation as quantum probes for temperature estimation with local and global dephasing — arXiv:2608.19344
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.19344
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-18T12:15:16.435Z
- SHA-256 of the archived text
ab95aaa208488bfd208e671eae3cdaff037a2496abb325ca62964d88ebfe26d1- Stable URL of this page
https://metraipolis.com/documento/dc_48c28ad99588
How to cite
Hyperon-antihyperon system in electron-positron annihilation as quantum probes for temperature estimation with local and global dephasing — arXiv:2608.19344 — arXiv (en), https://arxiv.org/abs/2608.19344 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_48c28ad99588 (Metraipolis archive dc_48c28ad99588, sha256 ab95aaa208488bfd208e671eae3cdaff037a2496abb325ca62964d88ebfe26d1)
BibTeX
@misc{dc48c28ad99588,
title = {Hyperon-antihyperon system in electron-positron annihilation as quantum probes for temperature estimation with local and global dephasing — arXiv:2608.19344},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.19344},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_48c28ad99588; sha256 ab95aaa208488bfd208e671eae3cdaff037a2496abb325ca62964d88ebfe26d1},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.19344. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
We investigate quantum thermometry in Ohmic-type reservoirs using two-qubit probes within an exactly solvable pure-dephasing framework. By analyzing the individual variance associated with temperature estimation, we identify optimal regimes governed by the Ohmicity parameter $s$, the deviation angle $\theta$, and the decay coefficients $\alpha$ and $\beta$, thereby determining the conditions that minimize estimation errors. The Quantum Fisher Information (QFI) exhibits pronounced maxima at finite interaction times, especially in sub-Ohmic and Ohmic environments at low temperatures, whereas super-Ohmic reservoirs flatten the QFI peak and shift the optimal sensitivity toward higher temperatures. Consistently, the quantum signal-to-noise ratio (QSNR) is suppressed at low temperatures, increases with thermal excitation, and saturates in the high-temperature regime, where the influence of spectral details becomes negligible. A comparative study of mutual and local estimation strategies shows that common-bath configurations, particularly for $\Sigma^+$ and $\Sigma^0$ probes, outperform local baths at short interaction times due to bath-induced correlations, while local environments become advantageous at longer times. The analysis further reveals finite optimal values of both the interaction time $t_{\rm opt}$ and the temperature $T_{\rm opt}$, as well as a strong reduction of the variance with increasing measurement number in the low-temperature regime. In addition, our study of hyperon-antihyperon channels ($\Lambda$, $\Sigma^+$, $\Sigma^0$, $\Xi^-$, $\Xi^0$) shows that entanglement and quantum discord remain remarkably robust over broad angular domains, whereas steering and Bell nonlocality are confined to narrower regions. Overall, the interplay between spectral structure, particle-dependent parameters, and estimation strategy provides valuable ...
Tema degli esploratori: fisica e astronomia (retro-catalogo arXiv: annunci del 2026-08-21 in quant-ph).
Categorie arXiv: Quantum Physics (quant-ph).
Pagina del lavoro: https://arxiv.org/abs/2608.19344 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-18T12:09:27.982Z dalla pagina https://arxiv.org/catchup/quant-ph/2026-08-21?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).